GENERAL
System Description
Furnish a _________________    (4-way multi-poise) fixed ca-
pacity gas-fired condensing furnace for use with natural gas or 
propane (factory authorized conversion kit required for pro-
pane); furnish cold air return plenum; furnish side (external) fil-
ter rack.
Quality Assurance
Unit will be designed, tested and constructed to the current 
ANSI Z 21.47/CSA 2.3 design standard for gas-fired central 
furnaces. 
Unit will be 3rd party certified by CSA to the current ANSI Z 
21.47/CSA 2.3 design standard for gas-fired central furnaces. 
Unit will carry the CSA Blue Star® and Blue Flame® labels.
Unit efficiency testing will be performed per the current DOE 
test procedure as listed in the Federal Register.
Unit will be certified for capacity and efficiency and listed in 
the latest GAMA Consumer’s Directory of Certified Efficiency 
Ratings.
Unit will carry the current Federal Trade Commission Energy 
Guide efficiency label.
Delivery, Storage, and Handling
Unit will be shipped as single package only and is stored and 
handled per unit manufacturer’s recommendations.
Warranty (for inclusion by specifying engineer)
U.S. and Canada only. Warranty certificate available upon re-
quest.
PRODUCTS
Equipment 
Components shall include: slow-opening gas valve to reduce ig-
nition noise, regulate gas flow, with electric switch gas shut-off; 
flame proving sensor, hot surface igniter, pressure switch as-
sembly verifies inducer operation; flame rollout switch, drain 
tubing and installed condensate drain trap, blower and inducer 
assembly, 40va transformer; low-voltage (heating) (heating/
cooling) thermostat.
Blower Wheel and Blower Motor
Galvanized blower wheel shall be centrifugal type, statically 
and dynamically balanced. Blower motor of PSC type shall be 
permanently lubricated with sealed bearings, of _____ hp, and 
shall be multiple-speed direct drive. Blower motor shall be soft 
mounted to the blower scroll to reduce vibration transmission.
Filters
Furnace shall have reusable-type filters. Filter shall be ______ 
in  (x) ______in.
Casing
Casing shall be of .030 in. thickness minimum, pre-painted gal-
vanized steel.
Inducer Motor 
Inducer motor shall be soft mounted to reduce vibration trans-
mission.
Primary Heat Exchangers
Primary Heat exchangers shall be 3-Pass 20 gauge corrosion re-
sistant aluminized steel of fold-and-crimp sectional design, 
which operates under negative pressure.  
Secondary Heat Exchangers
Secondary Heat exchangers shall be of a flow-through design 
having a patented interior laminate coating of polypropylene for 
greater corrosion resistance with fold-and-crimp design, which 
operates under negative pressure.
Controls
Controls shall include a micro-processor based integrated elec-
tronic control board with at least 11 service troubleshooting 
codes displayed via diagnostic flashing LED light on the con-
trol, has ability to store fault codes, when activated a self-test 
feature checks all major functions of the furnace within one 
minute, and a replaceable automotive-type circuit protection 
fuse.  Multiple operational settings available including separate 
blower speeds.  Cooling airflow will be selectable between 350 
or 400 CFM per ton of air conditioning. 
Operating Characteristics
Heating Capacity shall be _________ Btuh input; 
____________ Btuh output capacity.
Fuel Gas Efficiency shall be 92% AFUE.
Air delivery shall be  __________ cfm minimum at 0.50 in. wg. 
external static pressure.
Dimensions shall be: depth __________ in.; width __________ 
in.; height _________ in. (casing only). Height shall be 
__________ in. with A/C coil and ____________ in. overall 
with plenum.
Electrical Requirements
Electrical supply shall be 115 volts, 60 Hz, single-phase (nom-
inal). Minimum wire size shall be _________ AWG; maximum 
fuse size or HACR-type, designated circuit breaker shall be 
_______ Amps. 
Special Features
Refer to section of the product data sheet identifying accesso-
ries and descriptions for specific features and available en-
hancements.
Guide Specifications
Base 90
Single-Stage Gas Furnace
58MCB