Installation, Start–Up, Operating and
Service and Maintenance Instructions
Read the entire instruction manual before starting the installation.
TABLE OF CONTENTS
Table 1 – Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS PROCE-
DURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
LOCATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
AIR FOR COMBUSTION AND VENTILATION . . . . . . . . . . . . . . 7
Table 2 – Minimum Free Area Required for Each Combustion Air
opening of Duct to Outdoors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Table 3 – Minimum Space Volumes for 100% Combustion, Ventila-
tion, and Dilution from Indoors . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Table 4 – Opening Dimensions - In. (mm) . . . . . . . . . . . . . . . . . 10
AIR DUCTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
GAS PIPING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Table 5 – Maximum Capacity of Pipe . . . . . . . . . . . . . . . . . . . . . 14
ELECTRICAL CONNECTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Table 6 – Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
INTELISENSE™ TECHNOLOGY . . . . . . . . . . . . . . . . . . . . . . . . . 17
ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
VENTING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Table 7 – Combined Appliance Maximum Input Rating
in Thousands of BTUh per Hour . . . . . . . . . . . . . . . . . . . . . . . . . 20
Table 8 – Minimum Allowable Input Rating of
Space-Heating Appliance in Thousands of BTUh per Hour . . . . 20
Table 9 Recommended Minimum Vent Height Per Furnace and Vent
Orientation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
AIR DELIVERY - CFM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Table 10 – Air Delivery - CFM (with filter)* . . . . . . . . . . . . . . . 24
Table 11 – Default Airflow Settings . . . . . . . . . . . . . . . . . . . . . . 28
FURNACE CONTROL PROGRAMMING
AND NAVIGATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Table 12 – System Status Display Codes. . . . . . . . . . . . . . . . . . . 28
Table 13 – Main Menu Options . . . . . . . . . . . . . . . . . . . . . . . . . . 29
SERVICE LABEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Table 14 – Test Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
ADJUSTMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Table 15 – Altitude Derate Multiplier for U.S.A. . . . . . . . . . . . . 33
Table 16 – Gas Rate (CU ft./hr). . . . . . . . . . . . . . . . . . . . . . . . . . 33
Table 17 Orifice Size* and Manifold Pressure (in. w.c.) for Gas Input
RateTabulated Data Based on 22,000 BTUh per burner . . . . . . . 34
Table 18 Orifice Size* and Manifold Pressure (in. w.c.) for Gas Input
Rate Tabulated Data Based on 21,000 BTUh per burner . . . . . . 34
SERVICE AND MAINTENANCE PROCEDURES. . . . . . . . . . . . 36
CARE AND MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Table 19 – Filter Size Information - In. (mm) . . . . . . . . . . . . . . . 38
SEQUENCE OF OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
TROUBLESHOOTING GUIDE . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
GAS FURNACE CHECKLIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
PARTS REPLACEMENT INFORMATION GUIDE . . . . . . . . . . . 47
MODEL NOMENCLATURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
TRAINING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
To learn more about this appliance and installation via a mobile device,
go to https://carrier.hvacpartners.com/NFC or use the QR code below.
To access airflow tables or troubleshooting guide on your mobile device
go to mlctraining.com/training/techdocs/81/ or use the QR code below.
To learn more about InteliSense, go to Carrier.hvacpartners.com/InteliSense
or use the QR code below.
A230211
A200103
Portions of the text and tables are reprinted from NFPA 54/ANSI Z223.1E, with permission of National Fire Protection Association, Quincy, MA
02269 and American Gas Association, Washington DC 20001. This reprinted material is not the complete and official position of the NFPA or ANSI
on the referenced subject, which is represented only by the standard in its entirety.
58SP0B/58SP1B
80% AFUE, Non-Communicating, Single Stage,
Variable 25-Speed, ECM Motor, 4-Way Multipoise,
Non-Condensing Gas Furnace with InteliSense™
Mobile App QR Code Airflow QR Code
Question and Answer IconNeed help?

Do you have a question about the Carrier 58SP0B and is the answer not in the manual?

Overview

This document describes the installation, start-up, operating, and service and maintenance instructions for a Carrier 58SP0B/58SP1B furnace. This furnace is a non-communicating, single-stage, variable 25-speed, ECM motor, 4-way multipoise unit designed for use with IntelliSense™ technology. It is designed to burn natural gas and can be converted to propane gas.

Function Description:

The Carrier 58SP0B/58SP1B furnace provides heating for residential and light commercial applications. It utilizes a variable 25-speed ECM motor for efficient airflow and integrates with IntelliSense™ technology for optimized performance. The furnace is multipoise, meaning it can be installed in upflow, downflow, or horizontal left/right configurations, offering flexibility for various installation scenarios. It is designed to be a non-communicating, single-stage furnace, providing reliable heating.

Important Technical Specifications:

  • Model Numbers: 58SP0B and 58SP1B.
  • Motor Type: Variable 25-speed ECM motor.
  • Fuel Type: Natural gas (convertible to propane).
  • AFUE: 80% (Annual Fuel Utilization Efficiency).
  • Multipoise: Can be installed in upflow, downflow, horizontal left, or horizontal right orientations.
  • IntelliSense™ Technology: Integrated for enhanced control and efficiency.
  • Input Capacities: Available in various BTU/hr ratings, such as 44,000, 66,000, 88,000, 110,000, 132,000, and 154,000 BTU/hr for natural gas.
  • Electrical Supply: 115-V, 60 Hz.
  • Minimum Vent Diameter: 5 inches (127 mm) for all configurations and input ratings.
  • Minimum Vertical Vent Height: Varies by furnace input and vent orientation, e.g., 10 feet (3.0 m) for 110,000 BTU/hr downflow.
  • Airflow Data: Detailed tables provide external static pressure (in. w.c.) for various unit sizes, airflow settings (Cont. Fan, Low Cooling, Heating, High Cooling), and external static pressures (0.1 to 0.9 in. w.c.). For example, a 045V14-12 unit in heating mode at 0.5 in. w.c. can deliver 385 CFM.
  • Default Airflow Settings: Specifies default airflow settings for heating, high cooling, low cooling, and constant fan modes for different unit sizes. For instance, a 045V14-12 unit has a default heating airflow of 7.
  • Minimum Clearances to Combustibles:
    • Top: 1 inch (25 mm)
    • Front: 1 inch (25 mm)
    • Rear: 0 inch (0 mm)
    • Sides: 0 inch (0 mm)
    • Bottom: 0 inch (0 mm)
    • Supply Duct: 1 inch (25 mm)
    • Return Air Duct: 0 inch (0 mm)
    • Flue Pipe: 1 inch (25 mm)
  • Gas Pressure:
    • Inlet Supply Pressure (Natural Gas): Minimum 4.5 in. w.c. (1.12 kPa), Maximum 10.5 in. w.c. (2.61 kPa).
    • Manifold Pressure (Natural Gas): 3.5 in. w.c. (0.87 kPa).
    • Inlet Supply Pressure (Propane Gas): Minimum 10.5 in. w.c. (2.61 kPa), Maximum 13.0 in. w.c. (3.23 kPa).
    • Manifold Pressure (Propane Gas): 10.0 in. w.c. (2.49 kPa).

Usage Features:

  • Flexible Installation: The multipoise design allows for installation in various orientations (upflow, downflow, horizontal left/right) to suit different building layouts and space constraints.
  • IntelliSense™ Technology: This feature provides advanced control and optimization of the furnace's operation, potentially leading to improved comfort and energy efficiency.
  • Quiet Operation: The variable 25-speed ECM motor contributes to quieter operation compared to single-speed motors, enhancing indoor comfort.
  • Gas Conversion: The furnace can be converted from natural gas to propane gas using an approved conversion kit, providing flexibility for different fuel availability.
  • Airflow Adjustments: The control board allows for adjustments to airflow settings for heating, cooling, and continuous fan operation, enabling customization for specific comfort needs.
  • Diagnostic Features: The furnace includes a 3-digit LED display on the control board for diagnostics, showing status codes and error codes to assist with troubleshooting.
  • J-Box Integration: Designed for easy electrical connection to a J-Box, simplifying wiring and installation.
  • Return Air Kit: Specific instructions are provided for installing a bottom return air kit and side return air kit, ensuring proper airflow for various configurations.
  • Leveling Legs: Adjustable leveling legs are included to ensure the furnace is installed level, which is crucial for proper drainage and operation.
  • Filter Rack: The furnace is designed to accommodate a 1-inch (25 mm) filter, with provisions for adding a 3/4-inch (19 mm) filter media box for enhanced filtration.

Maintenance Features:

  • Filter Replacement: Regular replacement of the air filter is crucial for maintaining good indoor air quality and furnace efficiency. The manual provides guidance on filter types and sizes.
  • Cleaning Heat Exchanger: Detailed instructions are provided for cleaning the heat exchanger, including steps for removing components and using appropriate tools. This is a critical maintenance task to ensure safe and efficient operation.
  • Igniter Replacement: Instructions for replacing the igniter are included, which is a common wear item that may need periodic replacement.
  • Blower Motor and Wheel Maintenance: Guidelines for maintaining the blower motor and wheel are provided, including cleaning and inspection to ensure proper airflow.
  • Gas Valve Inspection: Regular inspection of the gas valve and gas piping is recommended to check for leaks and ensure safe operation.
  • Electrical Connections Check: Periodic checks of all electrical connections are advised to ensure they are secure and free from corrosion.
  • Condensate Drain Maintenance: Instructions for maintaining the condensate drain system are included to prevent blockages and ensure proper drainage.
  • Troubleshooting Guide: A comprehensive troubleshooting guide is provided, including flowcharts and error code explanations, to assist technicians and homeowners in diagnosing and resolving common issues.
  • Service Label: A service label with a QR code provides quick access to status codes and troubleshooting information.
  • Parts Replacement Information: A list of replacement parts is provided, categorized by component group (e.g., casing group, electrical group, blower group, gas control group, heat exchanger group, inducer group), to facilitate ordering and replacement.
  • Training: Information on available training resources (e.g., HVACPartners program, mlctraining.com) is provided for technicians to enhance their knowledge and skills.

Carrier 58SP0B Specifications

General IconGeneral
BrandCarrier
Model58SP0B
CategoryFurnace
LanguageEnglish