Installation, Start---up, Ope ra ting and
Service and Maintenance Instructions
58SU0A
4 --- W a y M u l t i p o i s e
Induced---Combustion, 80% AFUE Gas Furnace
Input Capacities: 40,000 thru 100,000 Btuh
SAFETY CONSIDERATIONS 2........................
INTRODUCTION 2..................................
CODES AND STANDARDS 4.......................
SAFETY 4......................................
GENERAL INSTALLATION 4......................
COMBUSTION AND VENTILATION AIR 4...........
DUCT SYSTEMS 4...............................
ACOUSTICAL LINING AND FIBROUS GLASS DUCT 5
GAS PIPING AND GAS PIPE PRESSURE TESTING 5...
ELECTRICAL CONNECTIONS 5...................
VENTING 5........................................
ELECTROSTATIC DISCHARGE
(ESD) PRECAUTIONS PROCEDURE 5...............
UPFLOW INSTALLATION 9.......................
DOWNFLOW INSTALLATION 10...................
HORIZONTAL INSTALLATION 11..................
AIR DUCTS 12...................................
GAS PIPING 15..................................
ELECTRICAL CONNECTIONS 18..................
115--V WIRING 18................................
J-- BOX RELOCATION 18..........................
24--V WIRING 19.................................
ACCESSORIES 19................................
VENTING 21.......................................
MASONRY CHIMNEY REQUIREMENTS 21..........
APPLIANCE APPLICATION REQUIREMENTS 22.....
ADDITIONAL VENTING REQUIREMENTS 24........
SIDEWALL VENTING 24..........................
START--UP, ADJUSTMENT, AND SAFETY CHECK 26.....
START--UP PROCEDURES 26......................
ADJUSTMENTS 26...............................
CHECK SAFETY CONTROLS 28...................
SERVICE AND MAINTENANCE PROCEDURES 31.......
ELECTRICAL CONTROLS AND WIRING 32.........
CARE AND MAINTENANCE 33....................
CLEANING AND/OR REPLACING AIR FILTER 33....
BLOWER MOTOR AND WHEEL 33.................
FLAME SENSOR CLEANING 34....................
CLEANING HEAT EXCHANGER 35.................
SEQUENCE OF OPERATION 36....................
FAULT CODE RECALL 37.........................
CLEAR FAULT MEMORY 37.......................
TROUBLESHOOTING 37..........................
COMPONENT TEST 37...........................
WIRING DIAGRAMS 38...........................
PARTS REPLACEMENT INFORMATION GUIDE 40....
Approved for installations up to 5,000 feet (1524 meters)
NOTE: Read the entire instruction manual before starting the
installation.
Portions of the text and tables are reprinted from current edition
of NFPA 54/ANSI Z223.1E, with permission of National Fire
Protection Association, Quincy, MA 02269 and American Gas
Association, Washington DC 20001. This reprinted material is
not the complete and of ficial position of the NFP A or ANSI on
the referenced subject, which is represented only by the standard
in its entirety.
Question and Answer IconNeed help?

Do you have a question about the Carrier 58SU0A040E17-12 and is the answer not in the manual?

Carrier 58SU0A040E17-12 Specifications

General IconGeneral
BrandCarrier
Model58SU0A040E17-12
CategoryFurnace
LanguageEnglish

Summary

Safety Considerations

Fire, Explosion, Electrical Shock, and Carbon Monoxide Poisoning Hazard

Critical hazards from improper operation, installation, or maintenance.

Furnace Reliability Hazard

Risks of premature component failure due to improper installation or misapplication.

Installation Standards and Procedures

Electrostatic Discharge (ESD) Precautions

Procedure to protect electronic components from static discharge damage.

Installation Hazards and Air Requirements

Fire and Installation Hazards

Warnings regarding improper furnace orientation and duct connections.

Furnace Corrosion Hazard

Risk of corrosion from contaminated air affecting heat exchangers.

Installation Procedures

Upflow Installation

Detailed steps for furnace installation in an upflow configuration.

Downflow Installation

Requirements for downflow installations, including floor bases.

Horizontal Installation and Air Ducting

Horizontal Installation Requirements

Guidelines for furnace placement and support in horizontal orientation.

Fire, Explosion, and Carbon Monoxide Hazards

Warnings specific to horizontal installation safety.

Carbon Monoxide and Poisoning Hazard

Warning about operating without a filter or with the access door removed.

Return Air and Gas Piping

Fire Hazard Warning

Warning against connecting return air ducts to the furnace back.

Gas Piping Hazards

Warnings related to gas piping installation, leaks, and purge procedures.

Furnace Overheat Hazard Caution

Caution to avoid damaging gas controls when connecting gas pipe.

Gas Piping Standards

Compliance with national and local codes for gas piping installation.

Electrical Connections and Wiring

Electrical Box and 24-V Wiring

Electrical Box Installation Hazards

Warnings for connecting electrical boxes to the furnace casing.

Venting Requirements

General Venting Guidelines

Rules for vent sizing, installation, and common venting practices.

Venting Precautions and Additional Requirements

Installation Hazard Warnings

Warnings for cut hazards and hot vent pipes during installation.

Start-Up, Adjustment, and Safety Checks

General Start-Up Procedures

Overview of initial steps for furnace start-up.

Fire and Explosion Hazards

Warnings related to gas leaks and testing procedures.

Furnace Adjustment Procedures

Steps for adjusting gas input rate and pressure.

Start-Up Procedures and Gas Checks

Furnace Overheat Hazard

Caution to prevent furnace damage by monitoring temperature rise.

Electrical Shock Hazard

Warning about electrical safety during procedures.

Safety Controls and Gas Valve Checks

Fire Hazard Warning

Warning about tightening gas valve taps to prevent leaks.

Safety Control Testing

Service and Maintenance Procedures

Fire, Injury, or Death Hazard Warning

Warning against performing maintenance without proper skills or tools.

Electrical Controls and Troubleshooting

Care and Maintenance

Fire and Explosion Hazard Warning

Warning against storing flammable or combustible items near the furnace.

Carbon Monoxide Poisoning Hazard

Warning about operating without a filter or with the access door removed.

Blower Motor and Flame Sensor Maintenance

Electrical Shock Hazard Warning

Warning regarding the blower access door switch and electrical safety.

Electrical Shock and Fire Hazard Warning

Warning to turn off power and gas before maintenance.

Heat Exchanger Cleaning and Ignitor Servicing

Sequence of Operation

Fire or Explosion Hazard Warning

Warning about gas line purging and leak testing.

Fault Code Management and Component Testing

Wiring Diagrams and Electrical Safety

Electrical Safety Hazards

Warnings about electrical shock, fire, and explosion during servicing.

Electrical Operation Hazards

Caution regarding wiring errors and proper polarity for furnace operation.

Service Guide and Fault Code Interpretation