53
Attach gaskets to vent pipe and
combustion air adapters.
Vent Coupling and Adapter
A13074
Fig. 39 -- Vent Coupling and Adapter with Gaskets
PSC INDUCER ASSEMBLY
INDUCER OUTLET
VENT ELBOW CLAMP
TORQUE 15 LB-IN.
VENT PIPE CLAMP
TORQUE 15 LB-IN.
VENT ELBOW
INDUCER OUTLET CHOKE
40,000 BTUH MODELS WITH
10 FT. (3.1 M) OF VENT OR LESS
A14277
Fig. 40 -- Inducer Vent Elbow
Avoid short horizontal osets with 90
deg. Elbows. Short osets can be
dicult to slope and may trap con-
densate.
Use 45 deg. Elbows where
possible, to ensure conden-
sate drainage.
Slope vent pipe back to the
furnace at least ¼” per foot
A14546
Fig. 41 -- Near Furnace Vent Connections