Guidelines for safely moving the unit using forklifts or slings, emphasizing correct lifting points.
Requirements for outdoor installation, level placement, and ensuring adequate space for operation and maintenance.
Electrical data including voltage, input power, current draw, and start-up current for the 040R-160R range.
Specifications for the power supply, including voltage range and warnings about incorrect voltage or phase imbalance.
Guidelines for selecting appropriate cable sections based on installation site regulations and unit requirements.
Details on the operating ranges for water and air temperatures for different unit configurations.
Precautions for water circuit connections, including analysis, treatment, and material compatibility.
Schematic diagrams and component keys for hydraulic circuits with and without hydraulic modules.
How variable speed pumps maintain constant pressure differential by adjusting pump speed based on pressure sensor readings.
How variable speed pumps maintain constant temperature difference by adjusting pump speed based on temperature sensors.
Charts showing available static pressure versus water flow rate for high pressure pumps.
Comprehensive checklist of visual and documentation checks required before initiating system start-up.
Steps for unit commissioning, including ensuring all checks are done and safety devices are operational.
Key checks for compressors, hydraulics, and refrigerant charge during system start-up.
Overview of the SmartVu™ control interface, its characteristics, and user-friendly features.
Explanation of the free cooling system using drycoolers to chill water, optimizing energy savings with low outdoor air temperatures.
Simple maintenance tasks for users, including visual inspections, cleaning air-cooled exchangers, and checking alarms.
Maintenance requiring specific expertise, including electrical, hydraulic, and mechanical checks, and component tightening.
Advanced maintenance tasks requiring manufacturer or qualified personnel, such as component replacement and refrigerant handling.
Table detailing torque values for tightening various electrical connections on components like compressors, contactors, and circuit breakers.
Table of torque values for tightening main fastenings on components such as compressor brackets, rails, and fan supports.
Checklist for shipping damage and its impact on unit start-up, and verification of installation, power supply, and wiring.
Checklist items for unit start-up, including pump cabling, oil level, leak checks, and voltage imbalance.
Checks for evaporator water loop volume, corrosion inhibitor, frost protection, electric tape heaters, and screen filter.
Procedure for checking evaporator pressure drop or ESP, and using curves to determine flow rate.
Instructions to perform and log the QUICK TEST function, including sequence, capacity, and setpoint configurations.
Guidance on recording stable operating temperatures and pressures for various circuits and components.