REPAIR PARTS
KEY NO. DESCRIPTION PART NO.
1 3/4-in. Relief Valve 157-00-01
2 3/4-in. Coupling 115-00-01
3 3/4-in. X 6-1/2-in. Nipple 146-07-002
4 Steam Pressure Gauge 146-23-005
5 1/4-in. Coupling 146-93-054
6 1/4-in. X 3-in. Nipple 146-07-001
7 AT-140D Transformer, 24v 146-62-045
8 PA-404A Pressuretrol 146-62-015
9 Glass Water Gauge Set (Used with PS-802 LWCO) 146-22-005
* Glass Water Gauge Set (Used with 67D-1 LWCO) 146-22-010
10 90° Pigtail (Used with PS-802 LWCO) 146-43-004
* 180° Pigtail (Used with 67D-1 LWCO) 146-43-005
11 PS-802 Low Water Cut-Off 128-00-01
* 67D-1 Low Water Cut-Off 146-26-042
12 Control, Intermittent Pilot UT 1003-620 146-62-070
* S8600M Intermittent Pilot Control, Liquified Petroleum Gas 146-62-071
13 1/2-in. X 3-in. Brass Nipple (PS-802 only) 131-00-03
14 1/2-in. X 1/2-in. X 1/4-in. Brass Tee (PS-802 only) 146-93-051
15 1/2-in. Brass Coupling (PS-802 only) 146-93-052
16 1/2-in. X 3 1/2-in. Brass Nipple (PS-802 only) 146-07-024
* 3/4-in. Drain Valve 146-22-000
* WF-2U-24 Water Feeder (Optional) 163-00-01
* Rollout Switch 146-29-002
* Spill Switch (36TX16-6282) 280°F 146-60-002
* 5-in. Vent Damper (3 Section Boilers) 118-20-05
* 6-in. Vent Damper (4, 5 Section Boilers) 118-20-06
* 7-in. Vent Damper (6, 7, 8, 9 Section Boilers) 118-20-07
* 400°F Black Silicone Rubber Adhesive Sealant (10.3 oz cartridge) 146-06-024
* Vent Damper Operator (Motor) 114-00-02
* Not illustrated.
A03137
4
5
1
9
10
6
8
7
11
13
14
12
2
3
BOILER CONTROLS AND PIPING