3
PHYSICAL DATA
UNIT SIZE SERIES 18---30 24---30 30---30,50 36---30,50,60 42---30,50,60 48---30,50,60 60---30,50,60
Operating Weight (lb) 135 135 149 166 210 236 261
Shipping Weight (lb) 156 156 171 189 238 264 295
Compressor Type Scroll
REFRIGERANT Puron® (R--- 410A)
Control TXV (Puron® Hard Shutoff)
Charge (lb) 4.25 4.35 4.75 5.25 6.2 8.35 8.75
COND FAN Propeller Type, Direct Drive
Air Discharge Vertical
Air Qty (CFM) 1880 2200 2200 2950 3170 3365 4050
Motor HP 1/12 1/10 1/10 1/4 1/5 1/4 1/5
Motor RPM 1100 1100 1100 1100 1100 1100 825
COND COIL
Face Area (Sq. ft.) 9.85 9.85 11.49 14.77 17.25 21.56 25.15
Fins per In. 20 20 25 25 25 25 25
Rows 1 1 1 1 1 1 1
Circuits 3 3 3 3 4 5 5
VALVECONNECT.(In.ID)
Vapor 5/8 5/8 3/4 3/4 7/8 7/8 7/8
Liquid 3/8
REFRIGERANT TUBES* (In. OD)
Vapor (0---80 Ft. Tube L ength) 5/8 5/8 3/4 3/4 7/8 7/8 1 --- 1 / 8
Liquid (0---250 Ft. Tube Length) 3/8
* For tubing sets between 80 and 200 ft. horizontal or 20 ft. vertical differential, consult the Longline Guideline.
Note: See unit Installation Instruction for proper installation.
VAPOR LI NE SIZI NG AND COOLING CAPACITY LOSS
PURON 1--STAGE AI R CONDITI ONER APPLICATIONS
LONG LINE APPLICATION: An application is considered ”long
line” when the total equivalent tubing length exceeds 80 ft or when
there is more than 20 ft. vertical separation between indoor and
outdoor units. These applications require additional accessories and
system modifications for reliable system operation. The maximum
allowable total equivalent length is 250Ft. The maximum vertical
separation is 200 Ft when outdoor unit is above indoor unit, and 80
ft. when the outdoor unit is below the indoor unit. Refer to
Accessory Usage Guideline for required accessories. See Long
Line Application Guideline for required piping and system
modifications. Also, refer to the table below for the acceptable
vapor tube diameters based on the total length to minimize the
cooling capacity loss.
UNIT
NOMINAL
SIZE
(BTUH)
ACCEPTABLE
LIQUID LINE
DIAMETERS
(IN. OD)
ACCEPTABLE
VAPOR LINE
DIAMETERS
(IN. OD)
COOLING CAPACITY LOSS (%)
TOTAL EQUIVALEN T LINE LENGTH (FT..)
Standard Application Long Line Application Requires Accessories
25 50 80 80+ 100 125 150 175 200 225 250
18000
1Stage
Puron AC
3/8
1/2 1 2 3 3 4 6 7 8 9 10 12
5/8 0 0 1 1 1 1 2 2 3 3 3
24000
1Stage
Puron AC
3/8
5/8 0 1 1 1 2 3 3 4 4 5 6
3/4 0 0 0 0 0 1 1 1 1 1 2
7/8 0 0 0 0 0 0 0 0 0 0 1
30000
1Stage
Puron AC
3/8
5/8 1 2 3 3 3 4 5 6 7 8 9
3/4 0 0 1 1 1 1 2 2 2 3 3
7/8 0 0 0 0 0 1 1 1 1 1 1
36000
1Stage
Puron AC
3/8
5/8 1 2 4 4 5 6 7 9 10 11 13
3/4 0 0 1 1 1 2 2 3 3 4 4
7/8 0 0 0 0 0 1 1 1 1 2 2
42000
1Stage
Puron AC
3/8
3/4 0 1 2 2 2 3 4 4 5 6 6
7/8 0 0 1 1 1 1 2 2 2 3 3
11/8 0 0 0 0 0 0 0 0 0 0 1
48000
1Stage
Puron AC
3/8
3/4 0 1 2 2 3 4 5 5 6 7 8
7/8 0 0 1 1 1 2 2 2 3 3 4
11/8 0 0 0 0 0 0 0 0 1 1 1
60000
1Stage
Puron AC
3/8
3/4 1 2 4 4 5 6 7 9 10 11 12
7/8 0 1 2 2 2 3 4 4 5 5 6
11/8 0 0 0 0 1 1 1 1 1 1 2
Standard Length = 80 ft. or less total equivalvent length
Applications in this area are long line. Accessories are required as shown recommended on Long Line Application Guideline
Applications in this area may have height restrictions that limit allowable total equivalent length, when outdoor unit is below indoor unit. See
Long Line Application Guideline.
24ACA3