EasyManua.ls Logo

Carrier DHMVHAQ24XA3 - Indoor PCB;Display Board Communication Error

Carrier DHMVHAQ24XA3
54 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
:
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
25
DIAGNOSIS AND SOLUTION (CONT.)
Indoor PCB/Display Board Communication Error ( )
Troubleshooting
Error Code
Malfunction decision conditions The indoor PCB does not receive feedback from the display board.
Supposed causes
Communication wire
Indoor PCB
Display board
Is it still displaying the error code?
The unit is functioning normally.
Check the wirings and connections.
Are all the connections
good?
Replace the indoor main PCB.
Does the error still exist?
Replace the display board.
Power o. Wait 2 minutes
then restart the unit.
Ensure a proper connection.
YES
NO
NO
YES