F97CMN and G97CMN: Installation, Start-up, Operating and Service and Maintenance Instructions
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
21
Table 7 – Cooling
4
and Heating Air Delivery - CFM (Bottom Return
5
With Filter)
(SW1-5 and SW4-3 set to OFF, except as indicated. See notes 1 and 2.)
Unit Size: 0601714 Clg/CF Switch settings External Static Pressure (ESP)
Clg Switches SW2-3 SW2-2 SW2-1 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Clg Default: OFF OFF OFF 1060 1070 1080 1080 1075 1065 1050 1035 1025 1010
CF Switches SW3-3 SW3-2 SW3-1
Low-Clg Default: OFF OFF OFF 545 530 520 525 510 See note 4
Cooling Airflow
(SW2)
Low-Cooling
Airflow (SW3)
OFF OFF ON 545 530 520 525 510 See note 4
OFF ON OFF 710 710 710 695 690 See note 4
OFF ON ON 875 880 890 895 895 890 885 880 870 855
ON OFF OFF 1060 1070 1080 1080 1075 1065 1050 1035 1025 1010
ON OFF ON 1235 1240 1250 1255 1255 1250 1230 1190 1155 1115
ON ON OFF 1235 1240 1250 1255 1255 1250 1230 1190 1155 1115
ON ON ON 1235 1240 1250 1255 1255 1250 1230 1190 1155 1115
Maximum Clg Airflow
2
1425 1425 1405 1370 1335 1300 1260 1225 1190 1155
CF Switches SW3-3 SW3-2 SW3-1
Cont. Fan Default: OFF OFF OFF 545 530 520 525 510 See note 4
Continuous Fan
Airflow (SW3)
OFF OFF ON 545 530 520 525 510 See note 4
OFF ON OFF 710 710 710 695 690 See note 4
OFF ON ON 875 880 890 895 895 890 885 880 870 855
ON OFF OFF 1060 1070 1080 1080 1075 1065 1050 1035 1025 1010
ON OFF ON 1060 1070 1080 1080 1075 1065 1050 1035 1025 1010
ON ON OFF 1060 1070 1080 1080 1075 1065 1050 1035 1025 1010
ON ON ON 1060 1070 1080 1080 1075 1065 1050 1035 1025 1010
Heating (SW1)
Maximum Heat Airflow
3
1075 1085 1095 1095 1090 1080 1065 1050 1035 1020
Intermediate Heat Airflow
3
535 515 505 515 495 See note 4
Minimum Heat Airflow
3
420 410 415 400 380 See note 4
Unit Size: 0602120 Clg/CF Switch settings External Static Pressure (ESP)
Clg Switches SW2-3 SW2-2 SW2-1 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Clg Default: OFF OFF OFF 1735 1735 1725 1715 1700 1685 1665 1650 1625 1605
CF Switches SW3-3 SW3-2 SW3-1
Low-Clg Default: OFF OFF OFF 540 525 525 520 540 See note 4
Cooling Airflow
(SW2)
Low-Cooling
Airflow (SW3)
OFF OFF ON 540 525 525 520 540 See note 4
OFF ON OFF 680 725 725 720 720 See note 4
OFF ON ON 925 915 910 895 900 890 875 865 860 855
ON OFF OFF 1070 1075 1080 1070 1080 1075 1055 1045 1030 1020
ON OFF ON 1215 1245 1235 1220 1220 1210 1200 1195 1185 1175
ON ON OFF 1380 1385 1395 1390 1395 1390 1380 1365 1355 1340
ON ON ON 1735 1735 1725 1715 1700 1685 1665 1650 1625 1605
Maximum Clg Airflow
2
1955 1950 1940 1925 1905 1885 1855 1815 1745 1685
CF Switches SW3-3 SW3-2 SW3-1
Cont. Fan Default: OFF OFF OFF 540 525 525 520 540 See note 4
Continuous Fan
Airflow (SW3)
OFF OFF ON 540 525 525 520 540 See note 4
OFF ON OFF 680 725 725 720 720 See note 4
OFF ON ON 925 915 910 895 900 890 875 865 860 855
ON OFF OFF 925 915 910 895 900 890 875 865 860 855
ON OFF ON 925 915 910 895 900 890 875 865 860 855
ON ON OFF 925 915 910 895 900 890 875 865 860 855
ON ON ON 925 915 910 895 900 890 875 865 860 855
Heating (SW1)
Maximum Heat Airflow
3
1080 1085 1095 1090 1095 1085 1070 1055 1045 1030
Intermediate Heat Airflow
3
685 725 730 725 730 See note 4
Minimum Heat Airflow
3
560 555 555 550 565 See note 4