(SW1-5 and SW4-3 set to OFF, except as indicated. See notes 1 and 2.)
Unit Size: 0801714 Clg/CF Switch settings External Static Pressure (ESP)
Clg Switches SW2-3 SW2-2 SW2-1 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Clg Default: OFF OFF OFF 1055 1065 1080 1075 1065 1050 1045 1035 1025 1005
CF Switches SW3-3 SW3-2 SW3-1
Low-Clg Default: OFF OFF OFF 520 505 505 495 490 See note 4
Cooling Airflow
(SW2)
Low-Cooling
Airflow (SW3)
OFF OFF ON 520 505 505 495 490 See note 4
OFF ON OFF 665 685 680 660 665 See note 4
OFF ON ON 885 895 905 900 900 895 885 875 860 845
ON OFF OFF 1055 1065 1080 1075 1065 1050 1045 1035 1025 1005
ON OFF ON 1245 1245 1255 1255 1260 1255 1250 1235 1220 1185
ON ON OFF 1245 1245 1255 1255 1260 1255 1250 1235 1220 1185
ON ON ON 1245 1245 1255 1255 1260 1255 1250 1235 1220 1185
Maximum Clg Airflow
2
1520 1485 1450 1415 1375 1335 1300 1265 1225 1190
CF Switches SW3-3 SW3-2 SW3-1
Cont. Fan Default: OFF OFF OFF 520 505 505 495 490 See note 4
Continuous Fan
Airflow (SW3)
OFF OFF ON 520 505 505 495 490 See note 4
OFF ON OFF 665 685 680 660 665 See note 4
OFF ON ON 885 895 905 900 900 895 885 875 860 845
ON OFF OFF 885 895 905 900 900 895 885 875 860 845
ON OFF ON 885 895 905 900 900 895 885 875 860 845
ON ON OFF 885 895 905 900 900 895 885 875 860 845
ON ON ON 885 895 905 900 900 895 885 875 860 845
Heating (SW1)
Maximum Heat Airflow
3
1520 1485 1450 1415 1375 1335 1300 1265 1225 1190
Intermediate Heat Airflow
3
755 745 755 755 765 See note 4
Minimum Heat Airflow
3
620 625 630 620 610 See note 4
Unit Size: 0802120 Clg/CF Switch settings External Static Pressure (ESP)
Clg Switches SW2-3 SW2-2 SW2-1 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Clg Default: OFF OFF OFF 1745 1755 1755 1760 1755 1750 1745 1725 1705 1685
CF Switches SW3-3 SW3-2 SW3-1
Low-Clg Default: OFF OFF OFF 700 710 750 725 750 See note 4
Cooling Airflow
(SW2)
Low-Cooling
Airflow (SW3)
OFF OFF ON 700 710 750 725 750 See note 4
OFF ON OFF 830 860 870 890 960 See note 4
OFF ON ON 1045 1045 1060 1070 1070 1070 1095 1090 1080 1070
ON OFF OFF 1215 1220 1245 1240 1235 1235 1225 1220 1235 1235
ON OFF ON 1370 1370 1390 1390 1400 1395 1400 1390 1390 1385
ON ON OFF 1745 1755 1755 1760 1755 1750 1745 1725 1705 1685
ON ON ON 1745 1755 1755 1760 1755 1750 1745 1725 1705 1685
Maximum Clg Airflow
2
1920 1920 1945 1945 1945 1960 1950 1940 1915 1900
CF Switches SW3-3 SW3-2 SW3-1
Cont. Fan Default: OFF OFF OFF 700 710 750 725 750 See note 4
Continuous Fan
Airflow (SW3)
OFF OFF ON 700 710 750 725 750 See note 4
OFF ON OFF 830 860 870 890 960 See note 4
OFF ON ON 1045 1045 1060 1070 1070 1070 1095 1090 1080 1070
ON OFF OFF 1215 1220 1245 1240 1235 1235 1225 1220 1235 1235
ON OFF ON 1370 1370 1390 1390 1400 1395 1400 1390 1390 1385
ON ON OFF 1370 1370 1390 1390 1400 1395 1400 1390 1390 1385
ON ON ON 1370 1370 1390 1390 1400 1395 1400 1390 1390 1385
Heating (SW1)
Maximum Heat Airflow
3
1340 1355 1370 1385 1380 1385 1400 1400 1385 1380
Intermediate Heat Airflow
3
780 810 835 840 845 See note 4
Minimum Heat Airflow
3
595 595 600 595 605 See note 4
Table 7 – Cooling
4
and Heating Air Delivery - CFM (Bottom Return
5
With Filter) (Continued)