EasyManua.ls Logo

Carrier Integra 35X - Refrigerant Charge; Operating Conditions; Initial Charge; TXV Setting

Carrier Integra 35X
30 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation & Commissioning Manual:
Neos 100S, 20X, 30S, 35X, 40X, 50X
62-11165 Rev D
®
4
Evaporator Clearances
Do not obstruct the evaporator fan
inlet(s) or outlet
For any movable bulkheads, there
must be a MINIMUM distance “A”
between the evaporator outlet and
any obstruction.
When mounting X Series
evaporators, it is recommended to
leave a MINIMUM distance “B” for
installation and service access.
MODEL
“A” Minimum Distance
Inches (millimeters)
“B” Minimum Distance
Inches (millimeters)
NEOS 100S, 20X
30S
35X,40X, 50X
20.0” (500)
32.0” (800)
40.0” (1,000)
6.0” (150)
Not Applicable
6.0” (150)
A
B

Other manuals for Carrier Integra 35X

Related product manuals