Installation & Commissioning Manual:
Neos 100S, 20X, 30S, 35X, 40X, 50X
62-11165 Rev D
®
6
Condenser Installation Roof Top Application
Install the four condenser mounting pads
by first applying waterproof silicone caulk
to the bottom cups in each pad.
Apply waterproof silicone caulk to each of the
four condenser mounting screws to prevent
water entry around the screw.
Remove the condenser cover. On the bottom cover of the
unit, drill the four 0.56” (15mm) mounting holes and the
larger electrical/hose hole as per the diagram on page 5.
Mount the condenser on the mounting pads in fasten in
place using the hardware supplied in the kit.
Apply waterproof silicone caulk to both sides of the center pad, which is used for
hoses and wiring, and install the center pad.