Installation & Commissioning Manual:
Neos 100S, 20X, 30S, 35X, 40X, 50X
62-11165 Rev D
®
1
INSTALLATION AND
COMMISSIONING MANUAL
for
Neos 100S
Integra 20X, 30S, 35X, 40X,
50X
Direct Drive Refrigeration Units
Truck Refrigeration
62-11165 Rev D
© 2017 Carrier Corporation • Printed in U. S. A. 0217
Question and Answer IconNeed help?

Do you have a question about the Carrier Integra 40X and is the answer not in the manual?

Carrier Integra 40X Specifications

General IconGeneral
CategoryAutomobile Accessories
TypeRoof Box
LockableYes
CompatibilityUniversal
ModelIntegra 40X
MaterialPlastic

Summary

Safety Precautions

Electrical Power Safety

Beware of HIGH VOLTAGE and automatic unit start.

Fan Blade Hazard

Beware of moving fan blades and parts; units may start automatically.

Vehicle Battery Safety

Keep flames away from vehicle battery due to flammable hydrogen gas.

Additional Safety Precautions

Electrical Connection Safety

Disconnect the battery ground (-) before electrical work.

Personal Protective Equipment

Always use personal protective equipment when servicing the unit.

Engine Coolant Hazard

Coolant is under high pressure and very hot; remove caps slowly.

Refrigerant Hazard

Refrigerant contact can cause frostbite, burns, or blindness.

Evaporator Mounting – Mushroom Drilling

Critical Drilling Caution

Ensure inner skin hole remains intact; do not drill all the way through roof.

Evaporator Mounting – Mushroom Installation

Refrigerant Hose Installation – Handling Recommendations

Proper Hose Routing and Bends

Avoid twisting/stressing hoses; use large bend radius and elbows.

Refrigerant Hose Installation – Installation Preparation

Refrigerant Hose Installation – Fitting Connection

Refrigerant Connection Lines – Neos 100S / 20X ONLY

Neos 100S/20X Line Routing Diagram

Diagram showing refrigerant line connections for Neos 100S/20X models from compressor to components.

Neos 100S/20X Line Specifications

Specifies line types (Hot Gas, Suction, Liquid, Discharge) and fitting sizes.

Refrigerant Connection Lines – 30S ONLY

30S Line Routing Diagram

Diagram showing refrigerant line connections for 30S models, including standby.

30S Line Specifications

Specifies line types (Hot Gas, Suction, Liquid, Standby, Discharge) and fitting sizes for 30S.

Refrigerant Connection Lines – 35X, 40X, 50X ONLY

35X/40X/50X Line Routing Diagram

Diagram showing refrigerant line connections for 35X/40X/50X models, including standby.

35X/40X/50X Line Specifications

Specifies line types (Hot Gas, Suction, Liquid, Standby, Discharge) and fitting sizes for 35X/40X/50X.

Electrical Connections

Battery and Ignition Harness Connections

Evacuation, Leak Checking, and Refrigerant Charging

Moisture Impact on System

Moisture causes sludge, freezing, corrosion; system must be kept dry.

Essential Evacuation Tools

Tools needed: vacuum pump (P/N 07-00176-01) and vacuum gauge indicator (P/N 07-00414-00).

Evacuation Process Steps

System Leak Testing

Perform leak check by drawing deep vacuum and verifying it holds.

Initial Vacuum Draw

Evacuate until vacuum gauge reads 2,000 microns; confirm vacuum holds.

Nitrogen Purge and Pressure Rise

Break vacuum with dry nitrogen, raise system pressure to ~2 psig.

Repeating Evacuation Procedure

Repeat the evacuation and nitrogen purge steps one more time.

Refrigerant Charging Procedure

Final Evacuation to 500 Microns

Evacuate to 500 microns; wait 5 minutes to check for residual moisture/leaks.

Charging Refrigerant by Weight

Charge refrigerant from container on weight scales; monitor scales for correct amount.

Verify Correct Refrigerant Type

Ensure the correct refrigerant type is used for each specific unit model.

Refrigerant Charge Specifications

Table provides refrigerant type and charge weight for each model.

Evaporator CPR Adjustment

CPR Valve Functionality

CPR regulates refrigerant flow to compressor, controls capacity, reduces load.

CPR Adjustment Conditions

Perform adjustment during road operation (2,400 RPM) or Heat/Defrost mode.

CPR Setting Values and Adjustment Factors

Evaporator TXV Setting

Evaporator TXV Superheat Adjustment