Refrigerant Hose Installation – Handling Recommendations
For proper functioning of the refrigeration unit,
the hoses must be kept clean and dry
It is recommended to leave the caps installed on
the ends of the hoses while routing them to
prevent internal damage or moisture entry.
Make sure to use the clamps provided in the installation kit to
secure the hoses and keep them from vibrating or rubbing.
Use the rubber grommets provided in the installation kit when
passing through holes and bulkheads to prevent the hoses and
electrical wires from rubbing on any sharp edges.
As shown in the diagram, do not twist, curve or
route the hoses in any manner which will stress
the hose. Use as large a bend radius as possible.
Use elbows and fitting as necessary to ease
installation and increase hose life.
When securing hoses, note the hoses will slightly change length
under pressure. When securing and clamping the hoses, make
sure to account for the slight variations in length that will occur.
Minimum Bend Radius
#6 hose (3/8”) 3.5” (90mm)
#8 hose (1/2”) 4.0” (100mm)
#10 hose (5/8”) 4.5” (115mm)
#12 hose (3/4”) 5.25” (135mm)