Installation & Commissioning Manual:
Neos 100S, 20X, 30S, 35X, 40X, 50X
62-11165 Rev D
®
4
Evaporator Clearances
Do not obstruct the evaporator fan
inlet(s) or outlet
For any movable bulkheads, there
must be a MINIMUM distance “A”
between the evaporator outlet and
any obstruction.
When mounting X Series
evaporators, it is recommended to
leave a MINIMUM distance “B” for
installation and service access.
MODEL
“A” Minimum Distance
Inches (millimeters)
“B” Minimum Distance
Inches (millimeters)
NEOS 100S, 20X
30S
35X,40X, 50X
20.0” (500)
32.0” (800)
40.0” (1,000)
6.0” (150)
Not Applicable
6.0” (150)
A
B