Installation & Commissioning Manual:
Neos 100S, 20X, 30S, 35X, 40X, 50X
62-11165 Rev D
®
21
Battery and Ignition Harness Connections
Route the neiman cable to the vehicle fuse box. Connect the wire
to the 1 Amp fuse holder supplied in the mounting kit.
Connect to a +12Volt DC switched circuit (refer to the specific
vehicle manufacturer’s recommendations).
Cut the battery harness to the required length. Strip back both the
positive (+) and negative (-) harness wires, crimp the electrical
terminals on, and connect to the corresponding terminals on the
fuse holder.
It is recommended to also use soft solder on the
terminal connections.
Mount road fuse holder as close as possible to the vehicle battery.
Put electrical grease on fuse holder connections, install the road
fuse supplied in the installation kit, and put protective cap on.
Connect the unit ground (-) to the vehicle chassis.
Re-connect the vehicle battery ground (-) to the battery.