EasyManua.ls Logo

Carrier MMY-MAP0724FT9UL - Page 233

Carrier MMY-MAP0724FT9UL
288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 233 –
Reactor assembly
(460V FT6UL)
No. Part to be replaced Work procedure Remarks
6-2
WARNING
Wear gloves.
Failure to wear gloves creates the risk of
personal injury by part replacement and
other objects.
1) Stop operation and turn off the breaker switch.
2) Remove the inverter assembly.
(Refer to “4. Removing the inverter assembly”.)
3) For 096 and 120 only, remove the separate
reactor box.
Remove the upper and lower screws (M5 x 0.4”
(10 mm)), slide the claw to the right, and then
remove the reactor box.
* Swing the reactor box upwards, slip it
downwards, and then pull it out.
For 096 and 120, remove the separate anchor plate.
(M4 × 0.2” (6 mm)6, 4 pcs)
4) Remove the reactor box, which is behind the inverter
assembly.
(M4 × 0.2” (6 mm), 4 pcs)
* Remove the screws starting from the front.
5) Remove the reactor and replace it.
(M4 × 0.2” (6 mm)6, 1 pc)
096type, 120type
072 type
3) Screw
Claw (Slide to the right.)
3) Screw
Claw (Slide to the right.)
4) Screw (2 locations)
4) Screw (2 locations)
4) Screw (2 locations)
4) Screw (2 locations)

Table of Contents