Display of selected functions
Table I: Unit protection devices
WARNING:
During heat pump operation the unit will undergo several defrost cycles to remove ice that might collect on the outdoor unit in very low ambient
temperatures. In these cycles, the indoor fan will be automatically off and cannot operate until defrost cycle is completed.
A
Remote control display for cooling only model
1. Signal transmission symbol
3. Cooling and dehumidification
4. Dehumidification only
5. Ventilation (fan only)
7. Temperature selected
8. Exhausted batteries
9. Unit on
10. Louvre control mode
11. Sleep timer
12. ON timer and OFF timer or current time
13. Fan speed
14. Everyday timer
Model Type of protection Effect of protection Operation mode When on
Indoor coil Compressor and Heating in
During unit operation
42PHQ / 42PHQ...K
high temp. protection outdoor fan off heat pump mode
(heat pump only)
Defrost cycle
Indoor fan off Heating in
During unit operation
outdoor fan off heat pump mode
Indoor coil
Compressor off Cooling During unit operation
42PHW / 42PHQ
freeze protection
42PHQ...K
Against frequent Compressor Cooling or heating At unit start-up or
compressor cycling time delay in heat pump mode change of operating mode
A
A
Remote control display for heat pump model
1. Signal transmission symbol
2. Automatic mode
3. Cooling and dehumidification
4. Dehumidification only
5. Ventilation (fan only)
6. Heating
7. Temperature selected
8. Exhausted batteries
9. Unit on
10. Louvre control mode
11. Sleep timer
12. ON timer and OFF timer or current time
13. Fan speed
14. Everyday timer