14
RVS/Heat Stage 2 O/B W2
Heat Stage 1 W/W1
Compressor Low Y1
Compressor High Y/Y2
Fan G
24VAC Hot Heating Rh
24VAC Hot Cooling Rc
Dry Contact 1 D1
Dry Contact 2 D2
24VAC Common C
Humidify HUM
Outdoor Air Temp OAT
Remote Room Sensor RRS
OAT/RRS Com OAT/RRS
Outdoor Sensor *
Humidifier Solenoid
Valve *
Remote Room
Sensor *
O
Y1
W1
G
W2
C
Y2
R
W1
Y1
O
Y/Y2
R
C
DH
REMOVE J2
JUMPER FOR
HEAT STAGING
REMOVE J1 FOR
DEHUMIDIFY
MODES
2 STAGE
HEAT PUMP
THERMIDISTAT
FAN
COIL
A08055
Fig. 10 -- Edge Thermidistat Models TP--PRH--01 or TP-- NRH --01)
Wiring with 2--Stage Heat Pump (non--communicating)
O
O/B W2 W2
W/W1 W/W1 W2 *
Heat/Cool Stage 1 Y1 / W2 Y1
Heat/Cool Stage 2 Y/Y2 Y/Y2 Y/Y2
Fan G G
24VAC Hot Heating Rh R R
24VAC Hot Cooling Rc
Dry Contact 1 D1
Dry Contact 2 D2
DHUM
24VAC Common C COM C
Humidify HUM
Outdoor Air Temp OAT
Remote Room Sensor RRS
OAT/RRS Com SRTN
Outdoor Sensor *
Humidifier Solenoid
Valve *
Remote Room
Sensor *
Variable Speed
Furnace
Thermidistat
2-Stage
Heat Pump
* Indicates connection may not be required / available.
Heat Stage 3 (furnace)
RVS Cooling
A09337
F i g . 1 1 -- T h e r m i d i s t a t M o d e l T P -- P R H -- 0 1 o r T P -- N R H -- 0 1 w i t h
Variable Speed Furnace and 2--Stage Heat Pump
(non--communicating)
D
C
B
A
User Interface
D
C
B
A
D
C
B
A
Communicating HP
OAT
RYOWCHUM
C
Humidifier
24vac
Furnace or Fan Coil
A08091
Fig. 12 -- Infinity Furnace or Fan Coil Wiring with Communicating 2--Stage HP
LEGEND
24v Factory Wiring
24v Field Wiring
Field Splice Connection
A09306
25HPA6