RGV-036-072-01SI 10-22
Installation Instructions
CONTENTS
Page
SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . 1
MODEL NUMBER NOMENCLATURE AND
DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Rated Indoor Airflow . . . . . . . . . . . . . . . . . . . . . 3
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Jobsite Survey . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Step 1 — Plan for Unit Location . . . . . . . . . . . . 8
ROOF MOUNT
Step 2 — Plan for Sequence of Unit
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
CURB-MOUNTED INSTALLATION
PAD-MOUNTED INSTALLATION
FRAME-MOUNTED INSTALLATION
Step 3 — Inspect Unit . . . . . . . . . . . . . . . . . . . . . 8
Step 4 — Provide Unit Support . . . . . . . . . . . . . 8
ROOF CURB MOUNT
SLAB MOUNT (HORIZONTAL UNITS ONLY)
ALTERNATE UNIT SUPPORT (IN LIEU OF CURB OR
SLAB MOUNT)
Step 5 — Field Fabricate Ductwork . . . . . . . . . 10
Step 6 — Rig and Place Unit . . . . . . . . . . . . . . 10
POSITIONING ON CURB
Step 7 — Convert to Horizontal and Connect
Ductwork (When Required) . . . . . . . . . . . . . 11
Step 8 — Install Outside Air Hood . . . . . . . . . 12
ECONOMIZER AND TWO-POSITION DAMPER
HOOD PACKAGE REMOVAL AND SETUP (FACTO-
RY OPTION)
ECONOMIZER AND 2-POSITION HOOD
Step 9 — Units with Hinged Panels Only . . . . 13
Step 10 — Install Flue Hood . . . . . . . . . . . . . . 13
Step 11 — Install Gas Piping . . . . . . . . . . . . . . 13
FACTORY OPTION THRU-BASE CONNECTIONS
(GAS CONNECTIONS)
Step 12 — Install External Condensate Trap and
Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Step 13 — Make Electrical Connections . . . . . 17
FIELD POWER SUPPLY
UNITS WITH FACTORY-INSTALLED NON-FUSED
DISCONNECT
UNITS WITHOUT FACTORY-INSTALLED
NON-FUSED DISCONNECT
ALL UNITS
CONVENIENCE OUTLETS
FACTORY-OPTION THRU-BASE CONNECTIONS
(ELECTRICAL CONNECTIONS)
UNITS WITHOUT THRU-BASE CONNECTIONS
(ELECTRICAL CONNECTIONS)
FIELD CONTROL WIRING
THERMOSTAT
HEAT ANTICIPATOR SETTINGS
HOT GAS RE-HEAT CONTROL CONNECTIONS
TYPICAL UNIT WIRING DIAGRAMS
Integrated Gas Controller . . . . . . . . . . . . . . . . 26
EconoMi$er
®
X (Factory Option) . . . . . . . . . . . 28
SYSTEM COMPONENTS
SPECIFICATIONS
INPUTS
OUTPUTS
ENVIRONMENTAL
ECONOMIZER MODULE WIRING DETAILS
S-BUS SENSOR WIRING
CO
2
SENSOR WIRING
INTERFACE OVERVIEW
SETUP AND CONFIGURATION
TIME-OUT AND SCREENSAVER
ENTHALPY SETTINGS
STANDARD OR SINGLE-SPEED FAN OPERATION
2 SPEED FAN OPERATION
2SP H/C (2-SPEED HEAT/COOL) FAN OPERATION
(SINGLE PHASE UNITS ONLY)
3 SPEED FAN OPERATION
CHECKOUT
TROUBLESHOOTING
Controller Options . . . . . . . . . . . . . . . . . . . . . . 41
LOW AMBIENT
Smoke Detectors . . . . . . . . . . . . . . . . . . . . . . . 41
Step 14 — Adjust Factory-Installed Options . 43
SMOKE DETECTORS
ECONOMI$ER
®
IV OCCUPANCY SWITCH
Step 15 — Install Accessories . . . . . . . . . . . . 43
Step 16 — Fan Speed Set Up . . . . . . . . . . . . . 44
UNITS WITH ELECTROMECHANICAL CONTROLS
START-UP CHECKLIST. . . . . . . . . . . . . . . . . CL-1
SAFETY CONSIDERATIONS
Installation and servicing of air-conditioning equipment can
be hazardous due to system pressure and electrical
components. Only trained and qualified service personnel
should install, repair, or service air-conditioning equipment.
Untrained personnel can perform basic maintenance
functions of cleaning coils and filters and replacing filters. All
other operations should be performed by trained service
personnel. When working on air-conditioning equipment,
observe precautions in the literature, tags and labels
attached to the unit, and other safety precautions that may
apply.
Follow all safety codes, including ANSI (American National
Standards Institute) Z223.1. Wear safety glasses and work
gloves. Use quenching cloth for unbrazing operations. Have
fire extinguisher available for all brazing operations.
It is important to recognize safety information. This is the
safety-alert symbol . When you see this symbol on the
unit and in instructions or manuals, be alert to the potential
for personal injury.
RGV036-072
Single Package Rooftop
Gas Heating/Electric Cooling Unit
with R-410A Refrigerant