Stages | 1 Heat/1 Cool |
---|---|
Voltage | 24V |
Display | LCD |
Backlight | Yes |
Temperature Range | 45°F to 90°F (7°C to 32°C) |
Hold Feature | Yes |
Filter Change Alert | Yes |
System Switch | Heat/Cool/Off |
Fan Control | Auto/On |
Power Source | Battery |
Battery | 2 AA Batteries |
Programmable | No |
Instructions on how to set the current time and day on the thermostat.
Guide to choosing between heating, cooling, auto, or program modes.
How to set desired heating and cooling temperatures using up/down buttons.
Explanation of how to manually control the fan or set it to automatic.
Overview of the buttons on the thermostat's front panel and their labels.
Detailed explanation of the icons, indicators, and information shown on the thermostat display.
Step-by-step instructions for setting the current time on the thermostat.
Instructions for selecting the current day of the week on the thermostat.
How to configure the thermostat for programmable or non-programmable operation.
Guide to manually selecting Heat, Cool, Auto, or Program On modes.
Detailed steps for adjusting heat and cool setpoints in Auto/Program or Heat/Cool modes.
How to access and view current, high, and low outside temperatures.
Instructions to display current indoor humidity and humidification setpoint.
Step-by-step guide to setting occupied and unoccupied periods and temperatures.
How to temporarily interrupt the programmed schedule for comfort adjustments.
Explanation of how to activate continuous fan operation or automatic fan mode.
How to program a delay for the fan to continue running after cooling is satisfied.
How to adjust the display backlight for different operating modes.
Setting the thermostat display to show temperature in Fahrenheit or Celsius.
How to prevent unauthorized access by locking or unlocking the thermostat keypad.
Setting security levels to limit temperature adjustments and program modes.
Instructions for physically installing the optional humidity module.
Setting the thermostat jumper for humidity operation.
How to set the desired humidity level for the system to maintain.
Setting the thermostat jumper for dehumidification operation.
How to set the desired dehumidification level for the system to maintain.
How to enable and configure the AC to assist with dehumidification.
Understanding the DEHUM terminal's function for dehumidification.
Tracking how long the thermostat has been in override mode.
Monitoring the operating hours of the humidification system.
Tracking the operating hours of the UV light system.
Configuring jumpers for heat pump and reversing valve operation.
Configuring the jumper for electric heat operation.
How to activate and use the emergency heat feature.
Setting the minimum temperature difference between heating and cooling setpoints.
Limiting the number of times the HVAC system can cycle per hour.
Setting deadbands for 1st, 2nd, and 3rd stage heating/cooling activation.
Configuring the minimum run-time required before engaging the next stage.
Determining when the second stage of heating or cooling will turn off.
How to activate the Energy Save feature for optimized energy usage.
Setting and resetting the alarm for fan run-time and filter replacement.
Setting and resetting the alarm for UV light operating hours.
Setting and resetting the alarm for humidifier operating hours.
How to program the number of days the holiday schedule will be enforced.
How to set jumpers for various functions like humidification, dehumidification, etc.
Detailed explanation of what each jumper setting controls.
How to restore the thermostat to its original factory settings.
Procedure for adjusting sensor calibration (requires HVAC technician).
Information on the RJ11 port and optional accessories like IR receivers and EZ Programmers.