Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Catalog No. 04-53500319-01 Printed in U.S.A. Form 50FC-16-01SI Rev. A Pg 1 2-22 Replaces: New
Installation Instructions
CONTENTS
Page
SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . 1
GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Rated Indoor Airflow (cfm) . . . . . . . . . . . . . . . . . . . . . 2
Pre-Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Step 1 — Plan for Unit Location . . . . . . . . . . . . . . . . 6
• RO
OF MOUNT
Step 2 — Plan for Sequence of Unit Installation . . . 6
• CURB-MOUNTED INSTALLATION
• PAD-MOUNTED INSTALLATION
• FRAME-MOUNTED INSTALLATION
Step 3 — Inspect Unit . . . . . . . . . . . . . . . . . . . . . . . . . 7
Step 4 — Provide Unit Support . . . . . . . . . . . . . . . . . 7
• ROOF CURB MOUNT
• SLAB MOUNT (HORIZONTAL UNITS ONLY)
• ALTERNATE UNIT SUPPORT (IN LIEU OF CURB OR
SLAB MOUNT)
Step 5 — Field Fabricate Ductwork . . . . . . . . . . . . . . 7
• FOR UNITS WITH ACCESSORY ELECTRIC HEATERS
Step 6 — Rig and Place Unit . . . . . . . . . . . . . . . . . . . 9
Step 7 — Convert to Horizontal and Connect . . . . 10
• ALL UNITS
Step 8 — Install Outside Air Hood . . . . . . . . . . . . . . 10
• TW
O-POSITION DAMPER HOOD REMOVAL
(FACTORY OPTION)
• ECONOMIZER AND TWO-POSITION DAMPER HOOD
SETUP
Step 9 — Install External Condensate Trap and
Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Step 10 — Make Electrical Connections . . . . . . . . . 12
• FIELD WIRING
• UNITS WITH FACTORY-INSTALLED NON-FUSED
DISCONNECT
• UNITS WITHOUT FACTORY-INSTALLED NON-
FUSED DISCONNECT
• CONVENIENCE OUTLETS
• ALL UNITS
• FACTORY-OPTION THRU-BASE CONNECTIONS
(ELECTRICAL CONNECTIONS)
Electric Heaters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
• SINGLE POINT BOXES AND SUPPLEMENTARY
FUSES
• SINGLE POINT BOXES WITHOUT FUSES
• LOW-VOLTAGE CONTROL CONNECTIONS
• HUMIDI-MIZER® CONTROL CONNECTIONS
• TYPICAL UNIT WIRING DIAGRAMS
EconoMi$er X (Factory-Installed Option) . . . . . . . . 25
• PRODUCT DESCRIPTION
• SYSTEM COMPONENTS
• SPECIFICATIONS
• INPUTS
• OUTPUTS
• ENVIRONMENTAL
• ECONOMIZER MODULE WIRING DETAILS
• S-BUS SENSOR WIRING
• CO2 SENSOR WIRING
• INTERFACE OVERVIEW
•
USER INTERFACE
• KEYPAD
• MENU STRUCTURE
• SETUP AND CONFIGURATION
• TIME-OUT AND SCREENSAVER
• STANDARD OR SINGLE SPEED FAN OPERATION
• 2 SPEED FAN OPERATION
• 2SP H/C (2 SPEED HEAT/COOL) SPEED FAN
OPERATION
• 3 SPEED FAN OPERATION
• ENTHALPY SETTINGS
• CHECKOUT
• TROUBLESHOOTING
SystemVu™ Controller (Factory Option) . . . . . . . . .36
• SMOKE DETECTORS
• COMPLETING INSTALLATION OF RETURN-AIR
SMOKE SENSOR
• ADDITIONAL APPLICATION DATA
Step 11 — Adjust Factory-Installed Options . . . . . .38
• SMOKE DETECTORS
• ECONOMI$ER X OCCUPANCY SWITCH
Step 12 — Install Accessories . . . . . . . . . . . . . . . . .38
Step 13 — Fan Speed Set Up . . . . . . . . . . . . . . . . . .38
• UNITS WITH ELECTRO-MECHANICAL CONTROLS
• UNITS WITH SYSTEMVU™ CONTROLS
START-UP CHECKLIST . . . . . . . . . . . . . . . . . . . . .CL-1
SAFETY CONSIDERATIONS
Installation and servicing of air-conditioning equipment can be
hazardous due to system pressure and electrical components. Only
trained and qualified service personnel should install, repair, or
service air-conditioning equipment.
Untrained personnel can perform basic maintenance functions of
cleaning coils and filters and replacing filters. All other operations
should be performed by trained service personnel. When working
on air-conditioning equipment, observe precautions in the
literature, tags and labels attached to the unit, and other safety
precautions that may apply.
Follow all safety codes. Wear safety glasses and work gloves. Use
quenching cloth for unbrazing operations. Have fire extinguisher
available for all brazing operations.
It is important to recognize safety information. This is the safety-
alert symbol . When you see this symbol on the unit and in
instructions or manuals, be alert to the potential for personal
injury.
WeatherMaker
®
50FC-*16
Single Package Rooftop Cooling Only
with Puron
®
(R-410A) Refrigerant
and EcoBlue™ Fan Technology