Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Catalog No. 04-53500422-01 Printed in U.S.A. Form No. 50FE-16-01SI Pg 1 4-24 Replaces: New
Installation Instructions
CONTENTS
Page
SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . 1
GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Rated Indoor Airflow (cfm) . . . . . . . . . . . . . . . . . . . . . 2
Pre-Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Step 1 — Plan for Unit Location . . . . . . . . . . . . . . . . 6
ROOF MOUNT
Step 2 — Plan for Sequence of Unit Installation . . . 6
CURB-MOUNTED INSTALLATION
PAD-MOUNTED INSTALLATION
FRAME-MOUNTED INSTALLATION
Step 3 — Inspect Unit . . . . . . . . . . . . . . . . . . . . . . . . . 7
Step 4 — Provide Unit Support . . . . . . . . . . . . . . . . . 7
ROOF CURB MOUNT
SLAB MOUNT (HORIZONTAL UNITS ONLY)
ALTERNATE UNIT SUPPORT (IN LIEU OF CURB OR
SLAB MOUNT)
Step 5 — Field Fabricate Ductwork . . . . . . . . . . . . . . 7
FOR UNITS WITH ACCESSORY ELECTRIC HEATERS
Step 6 — Rig and Place Unit . . . . . . . . . . . . . . . . . . . 9
Step 7 — Convert to Horizontal and Connect . . . . 10
ALL UNITS
Step 8 — Install Outside Air Hood . . . . . . . . . . . . . . 10
ECONOMIZER HOOD SETUP
Step 9 — Install External Condensate Trap and
Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Step 10 — Make Electrical Connections . . . . . . . . . 11
•FIELD WIRING
UNITS WITH FACTORY-INSTALLED NON-FUSED
DISCONNECT
UNITS WITHOUT FACTORY-INSTALLED
NON-FUSED DISCONNECT
CONVENIENCE OUTLETS
ALL UNITS
FACTORY-OPTION THRU-BASE CONNECTIONS
(ELECTRICAL CONNECTIONS)
Electric Heaters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
SINGLE POINT BOXES AND SUPPLEMENTARY
FUSES
SINGLE POINT BOXES WITHOUT FUSES
LOW-VOLTAGE CONTROL CONNECTIONS
HUMIDI-MIZER
®
CONTROL CONNECTIONS
TYPICAL UNIT WIRING DIAGRAMS
Humidi-MiZer Dehumidification System
(Optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
NORMAL COOLING
DEHUM/MECH COOLING (SUBCOOLING) MODE
DEHUMIDIFICATION (HOT GAS REHEAT) MODE
REHEAT CONTROL
Leak Dissipation System . . . . . . . . . . . . . . . . . . . . .27
SEQUENCE OF OPERATION
LEAK DISSIPATION SYSTEM SELF-TEST
TROUBLESHOOTING
EconomizerONE (Factory Option) . . . . . . . . . . . . . .30
ECONOMIZER SETTINGS
•WIRING
SETUP AND CONFIGURATION
INSTALLING OPTIONAL HH57LW001 SINGLE
OUTSIDE AIR ENTHALPY SENSOR
CHECKOUT
TROUBLESHOOTING
SystemVu™ Controller (Factory Option) . . . . . . . . .51
SMOKE DETECTORS
COMPLETING INSTALLATION OF RETURN-AIR
SMOKE SENSOR
ADDITIONAL APPLICATION DATA
Step 11 — Adjust Factory-Installed Options . . . . . .52
SMOKE DETECTORS
ECONOMIZERONE OCCUPANCY SWITCH
Step 12 — Install Accessories . . . . . . . . . . . . . . . . .52
Step 13 — Fan Speed Set Up . . . . . . . . . . . . . . . . . .52
UNITS WITH ELECTRO-MECHANICAL CONTROLS
UNITS WITH SYSTEMVU™ CONTROLS
START-UP CHECKLIST . . . . . . . . . . . . . . . . . . . . . CL-1
SAFETY CONSIDERATIONS
Installation and servicing of air-conditioning equipment can be
hazardous due to system pressure and electrical components. Only
trained and qualified service personnel should install, repair, or
service air-conditioning equipment.
Untrained personnel can perform basic maintenance functions of
cleaning coils and filters and replacing filters. All other operations
should be performed by trained service personnel. When working
on air-conditioning equipment, observe precautions in the
literature, tags and labels attached to the unit, and other safety
precautions that may apply.
Follow all safety codes. Wear safety glasses and work gloves. Use
quenching cloth for unbrazing operations. Have fire extinguisher
available for all brazing operations.
It is important to recognize safety information. This is the
safety-alert symbol . When you see this symbol on the unit and
in instructions or manuals, be alert to the potential for personal
injury.
Understand the signal words DANGER, WARNING, CAUTION,
and NOTE. These words are used with the safety-alert symbol.
DANGER identifies the most serious hazards which will result in
severe personal injury or death. WARNING signifies hazards
which could result in personal injury or death. CAUTION is used
to identify unsafe practices, which may result in minor personal
injury or product and property damage. NOTE is used to highlight
suggestions which will result in enhanced installation, reliability,
or operation.
WeatherMaker
®
50FE-*16
Single Package Rooftop Cooling Only
with Puron Advance(R-454B) Refrigerant
and EcoBlue™ Fan Technology

Table of Contents