SOME ADVICE
Before loading
D Pre--cool the inside of the insulated body by lowering the temperature for about 15 minutes.
D Evacuate the humidity existing inside the box by carrying out a manual defrost. This can only take place
when enabled by the defrost thermostat (box temperature lower than 3_C.
D Evaporator fans are protected by safety grills. In the event of heavy duty use of the unit, ice can accumulate
on the grills. It is therefore recommended to clean them regularly by means of a small brush. The operation
MUST be done when the unit has been SHUT DOWN.
When loading
D To be carried out with the unit stopped.
D It is recommended to open doors as little as possible to avoid the intake of hot air and humidity.
D Select the temperature by means of the thermostat, according to the transported goods.
D Check the internal temperature of the goods being loaded (using a probe thermometer).
Load spacers
Load on pallets
D Take care not to obstruct the air intakes on
the evaporator section and the ventilation
ducts.
D Leave a free space of about :
- 6 to 8 cm between load and frontwall,
- 20 cm between the top of the load and the
roof,
- between the floor and the load (gratings,
pallets).
D Do not forget to close the doors.
D Before closing the doors, check your load once more and see that nobody is shut inside the box.
NOTE :
For stationnary utilization, we recommend
to place the body in the shade.
IMPORTANT
Never leave your unit more than a month
without running.