ZONECC3Z(AC/HP)01
3---Zone Control System
Quick Reference Guide
ZONECC3ZAC01
1Heat/1Cool
ZONECC3ZHP01
3Heat/2CoolHP
INTRODUCTION
The Carrier 3--Zone Control system brings the possibility of total
comfort control to the occupants by providing the right amount of
heating or cooling for up to 3 distinct spaces or zones within a
home or business. Each zone has independent temperature settings
controlled by a conventional thermostat or Wi--Fir based
thermostats and up to 5 dampers per zone.
The Quick Reference Guide will provide a simplified description
on installing the 3--Zone Control System. Please reference the
Installation and Start- Up Instructions included in the 3-- Zone
Controller packaging for the complete design and installation
information on the 3--Zone System.
PRODUCT FEATURES AND BENEFITS
S Duct Temperature Optimizer -- Offers maximum equipment
protection to help ensure long life.
S Wi--Fir Thermostat compatibility -- Matches the right thermostat
to the homeowner s comfort and lifestyle.
S Diagnostic LEDs -- Intelligent system diagnostics to let
homeowners know if there is a problem with their system.
S Emergency Heat Switch -- Allows manual override for
emergency heat strip operation when utilizing a heat pump.
S Max Cycle Rate -- Allows 4 equipment cycles per hr (cph)
providing maximum equipment protection.
S Selection Jumpers -- Designed for easy configuration
S Additional Options
S Timeguard override
S Compressor protection
S Modulating damper control in emergency situations
S Damper fuse protection
S High and low temperature limits
S Auto changeover from any zone
S RH and RC for voltage isolation
S Bypass setup routine
S Staging time for energy savings
S Automatic checkout with installer mode
S Override zoning switch
S Timer override for serviceability
COMPONENTS NEEDED
3--Zone Control Panel
S Separate transformer is not needed to provide power
S Designed so that wires can enter from behind, above, or below
S Each system controller also includes a duct temperature sensor
24v or Wi --Fir Thermostats
S Advanced energy savings algorithms
S Remote access
TSTWHA01
Côr 7C
Thermostat
TP --WEM01 --A
r Thermostat
Dampers (8--in. -- 24--in.)
S Up to five dampers may be used in each zone by electrically
connecting them in parallel
S By-- pass damper available to prevent static pressure buildup
AIRFLOW
AIRFLOW
C
L
S
C
O
M
O
P
N
C
L
S
C
O
M
O
P
N
A05252
A05251
Rectangular
Damper
Round Da mper
By --Pass
Leaving Air Temperature
(LAT) Sensor
Slip--In Damper
Fig. 1 -- Damper Types
NOTE: Thermostats and Dampers are sold separately .
W i --- F i R is a registered trademark of the Wi---Fi Alliance Corporation
Question and Answer IconNeed help?

Do you have a question about the Carrier ZONECC3ZAC01 and is the answer not in the manual?

Carrier ZONECC3ZAC01 Specifications

General IconGeneral
BrandCarrier
ModelZONECC3ZAC01
CategoryControl Systems
LanguageEnglish

Summary

Components Needed

Component Location and Wiring Considerations

Locating Carrier 3-Zone System

Guidance on selecting an appropriate indoor location for the 3-Zone Control System, considering wiring access.

Mounting the Carrier 3-Zone System

Instructions for physically mounting the 3-Zone Control System unit in a vertical or horizontal position.

Install Thermostats in each desired Zone

Steps for installing thermostats in each zone and connecting their wires to the 3-Zone Control Panel.

Installation Steps

Install Leaving Air Temperature (LAT) Sensor / Heat Pump Temperature (HPT) Sensor

Guidance on installing LAT and optional HPT sensors for monitoring and protecting HVAC equipment.

Wire the HVAC Equipment

Guidance on selecting the correct wiring diagram and setting dipswitches based on system configuration.

Dipswitch Settings

Wiring Diagrams for System Configurations

Related product manuals