INTRODUCTION
PIPETHREADFITTINGTORQUE
Beforeinstallingandtighteningpipettings,cleanthe
threadswithacleansolventorLoctitecleanerandapply
sealantLOCTITE®567PSTPIPESEALANTforallttings
includingstainlesssteelorLOCTITE®565PSTformost
metalttings.Forhighltration/zerocontaminationsys-
temsuseLOCTITE®545.
PIPETHREADFITTING
ThreadSize
Torque(Maximum)
1/8-2713N·m(10lbft)
1/4-1816N·m(12lbft)
3/8-1822N·m(16lbft)
1/2-1441N·m(30lbft)
3/4-1454N·m(40lbft)
INSTALLATIONOFORFS(O-RINGFLAT
FACED)FITTINGS
WheninstallingORFSttingsthoroughlycleanbothat
surfacesofthettings(1)andlubricatetheO-ring(2)with
lightoil.Makesurebothsurfacesarealignedproperly.
Torquethettingtospeciedtorquelistedthroughoutthe
repairmanual.
NOTICE:Ifthettingsurfacesarenotproperlycleaned,
theO-ringwillnotsealproperly.Ifthettingsurfacesare
notproperlyaligned,thettingsmaybedamagedandwill
notsealproperly.
NOTICE:Alwaysusegenuinefactoryreplacementoils
andlterstoensureproperlubricationandltrationofen-
gineandhydraulicsystemoils.
Theuseofproperoils,grease,andkeepingthehydraulic
systemcleanwillextendmachineandcomponentlife.