IGNITION TIMING
Every 100 hours of operation, the breaker
point cover should be removed and the points
cleaned and reset. Pitted or burned points
should be replaced. Regap the points to .020
inch. Loosen the point retaining screw and
using a screwdriver in the adjusting slot,
increase or decrease the point gap to obtain
.020 inch, Figure F-13. Retighten the point
retaining screw.
Running Timing
The timing can be checked by removing
the plug from the timing hole located on the
left hand side of the bearing plate.
When the running timing is checked with
a timing light the SP mark must be center-
ed in the timing hole, Figure F-15.
If not,
adjust the breaker points as described above.
Figure F-13
0
Figure F-15
IGNITION COIL SPECIFICATIONS
Delco Remy No.
Case No.
Resistance, OHMS at 75° F.
Primary
I Secondary
1115070
KO 231281
3.40-4.20
I
3000 - 20,000
IGNITION CONDENSER SPECIFICATIONS
Delco Remy No. Case No. Capacitance
1942948
KO 230722
.18 to .23 MFD.
F-8