EasyManua.ls Logo

Case 2 Series - Electrical equipment

Case 2 Series
41 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
INTRODUCTION
NOTICE:Operationofthehydraulicequipmentwithoutllinghydraulicoilorlubricantorwithoutperformingair
bleedingwillresultindamagetotheequipment.
3.Performairbleedingofthehydraulicpumpandslewingmotorafterlooseningtheupperdrainplug,startingthe
engineandkeepitinlowidlecondition.
Completetheairbleedingwhenseepingofhydraulicoilisrecognized,andtightlyplug.
4.Performairbleedingofthetravelmotorandthehydrauliccylindersbyrunningtheengineformorethan5min
atlowspeedwithoutload.
NOTICE:Donotallowthehydrauliccylindertobottomonthestrokeendjustafterthemaintenance.
5.Performairbleedingofpilotlinebyperformingaseriesofdigging,slewingandtravel.
6.Checkhydraulicoillevelafterplacingtheattachmenttotheoilcheckposition,andreplenishoilifnecessary.
Electricalequipment
1.Donotdisassembleelectricalequipment.
2.Handleitcarefullynottodropandgiveashock.
3.TurnthekeyOffpriortoconnectinganddisconnectingwork.
4.Disconnecttheconnectorbyholdingitandpressingthelock.Donotpullthewiretoapplyforcetothecaulking
portion.
5.Connecttheconnectorandensureitiscompletelylocked.
6.TurnthekeyOffpriortotouchingtheterminalofstarterorgenerator.
7.Removetheground(earth)terminalofbatterywhenhandlingtoolsaroundthebatteryoritsrelay.
8.Donotsplashwaterontheelectricalequipmentandconnectorsduringmachinewashing.
9.Checkformoistureadhesioninsidethewaterproofconnectorafterpullingitout,sinceitishardtoremovemois-
turefromtheconnector.
Ifmoistureadhesionisfound,dryitcompletelybeforetheconnection.
Batteryelectrolyteishazardous.
Batteryelectrolyteisdilutesulfuricacid.Exposureofskinoreyestothisliquidwillcauseburningorlossofeyesight.
Iftheexposureoccurs,takethefollowingemergencymeasuresandseektheadviceofamedicalspecialist.
Whenskinexposed:
Washwithwaterandsoapsufciently.
Wheneyesexposed:
Immediatelywashawaywithcitywatercontinuouslyformorethan10min.
Whenalargeamountoftheliquidowsout:
Neutralizewithsodiumbicarbonateorwashawaywithcitywater.
Whenswallowed:
Drinkalargeamountofmilkorwater.
Whenclothesexposed:
Immediatelyundressandwash.