INTRODUCTION
Hydrauliccontamination
SR270TIER4B(FINAL)[NFM481941-]
NA
SV300TIER4B(FINAL)[NFM470295-]
NA
TR340TIER4B(FINAL)[NFM482972-]
NA
TV380TIER4B(FINAL)[NFM483044-]
NA
Contaminationinthehydraulicsystemisamajorcauseofthemalfunctionofhydrauliccomponents.Contamination
isanyforeignmaterialinthehydraulicoil.
Contaminationcanenterthehydraulicsysteminseveralways:
Whenyoudraintheoilordisconnectanyline
Whenyoudisassembleacomponent
Fromnormalwearofthehydrauliccomponents
Fromdamagedsealsorwornseals
Fromadamagedcomponentinthehydraulicsystem
Allhydraulicsystemsoperatewithsomecontamination.Thedesignofthecomponentsinthishydraulicsystemper-
mitsefcientoperationwithasmallamountofcontamination.Anincreaseinthisamountofcontaminationcancause
problemsinthehydraulicsystem.
Thefollowinglistincludessomeoftheseproblems:
Cylinderrodsealsthatleak
Controlvalvespoolsthatdonotreturntoneutral
Movementofcontrolvalvespoolsisdifcult
Hydraulicoilthatbecomestoohot
Pumpgears,housing,andotherpartsthatwearrapidly
Reliefvalvesorcheckvalvesheldopenbydirt
Quickfailureofcomponentsthathavebeenrepaired
Slowcycletimesareslow.Themachinedoesnothaveenoughpower.
Ifyourmachinehasanyoftheseproblems,checkthehydraulicoilforcontamination.
Therearetwotypesofcontamination:microscopicandvisible.
Microscopiccontaminationoccurswhenveryneparticlesofforeignmaterialaresuspendedinthehydraulicoil.
Theseparticlesaretoosmalltoseeorfeel.Microscopiccontaminationcanbefoundbyidenticationofthefollowing
problemsorbytestinginalaboratory.
Examplesofproblemscausedbymicroscopiccontamination:
Cylinderrodsealsthatleak
Controlvalvespoolsthatdonotreturntoneutral
Thehydraulicsystemhasahighoperatingtemperature
Visiblecontaminationisforeignmaterialthatcanbefoundbysight,touch,orodor.Visiblecontaminationcancause
asuddenfailureofcomponents.
Examplesofproblemscausedbyvisiblecontamination:
Particlesofmetalordirtintheoil
Airintheoil
Darkorthickoil
Oilwithanodorofburnedoil
Waterintheoil
Ifyoundcontamination,useaportableltertocleanthehydraulicsystem.
4768516124/06/2015