— 9 —
How to transfer the data
1. Under calculator mode, set the date of the slave unit to Feb. 3rd, 1901.
Operation : ON OK 1 DATE 2 DATE 3 DATE M+
If you do not set the date, the "PASSWORD" is not transferred to the slave unit.
2. Check the hardware parameters of both unit, and if both units have another condition, reset as follows;
MENU FUNC 2 3
3. Set up the slave unit.
• On the desktop, select the telephone icon
and press OK .
• Select the home icon and press OK .
• FUNC 2 2
4. Set up the customer's unit.
MENU FUNC 2 1 3 OK
If you can not succeed to transfer the data, press ESC key on both units and try to transfer the data again
following the procedure above.
TO STOP
PRESS [ ESC ]
DATA
RECEIVE OK!
OK
TO STOP
PRESS [ ESC ]
DATA
SENDING!
//////////// SET UP PAR. ////////////
PARITY E/O/NN
BIT LENGTH 77 / 8
BPS 4800 / 96009600
TO SAVE THE DATA
CSF-4450A/4650A/4950A/4970A can transfer the customer's data to another CSF unit with memory
protection only when replacing the LCD or the outer case.
To connect the CSF Unit to another CSF Unit
1. Make sure that the power of both units are switched off.
2. Remove the covers from the data communications jacks on the two CSF Units.
3. Connect the two units using the SB-62 cable.