242
Error
Messages
Ener
code!
Cause
Countermeasure
Error
1
Unable
to
write
programs
or
ex-
|
#
Erase
unnecessary
programs
Memory
over
pand
variables
due
to
insufficient
with
the
NEW
command
or
or
system
capacity
of
free
area.
reduce
the
number
of
stack
over
variables.
@
Calculating
area
(stack)
unable
Separate
and
simplify
the
to
hold
formula
since
the
formula,
formula
is
excessively
complex.
@
Unable
to
write
data
in
the
data
e
Clear
the
array
bank
since
capacity
is
insuffi-
cient.
«
Nine
or
more
arrays
were
declared.
Error
2
e
Format
error
in
the
program
or
e
Correct
the
error
in
the
input
Syntax
error
formula.
e
The
formats
of
left
side
and
right
side
in
the
assigned
statement
differ.
(Such
as
character
type
and
numeric
type)
Attempted
to
read
character
in
a
numeric
variable
with
READ/
READ#.
Character
string
operation
ex-
ceeded
62
characters.
program.
#
Change
numeric
variable
to
character
variable
or
check
for
character
(including
space)
in
the
DATA
statement.
e
Shorten
the
character
string.
Error
3
Mathematical
error
@
When
the
calculation
result
of
a
formula
exceeds
10'°°.
(Over-
flow)
e
When
arguments
are
outside
the
input
range
of
numeric
func-
tions.
e
When
the
results
are
uncertain
or
impossible.
(Attempted
to
divide
with
a
Q)
©
Correct
the
formula
or
the
data.
@
Check
the
data.
Error
Messages
Error
code/
Meaning
Cause
Countermeasure
Error
4
Undefined
error
©
No
jump
destination
for
the
GOTO
or
GOSUB
statements.
There
is
no
data
to
be
read
with
READ/READ#
or
RESTORE#.
e
The
line
number
specified
with
RESTORE
does
not
exist.
@
Specify
the
correct
jump
destination.
@
Write
data
e
Correct
the
line
number.
Error
5
Argument
error
e
When
the
argument
is
outside
the
input
range
of
commands
and
functions
requiring
argu-
ments,
The
subscript
in
the
array
is
out-
side
the
input
range.
®
Attempted
to
specify
two
arrays
with
the
same
name
but
differ-
ent
subscripts.
@
Correct
the
argument
error.
e
Change
the
subscript.
Change
the
array
name.
Error
6
Variable
error
e
Attempted
to
use
a
variable
that
was
not.added.
©
Attempted
to
use
the
same
varia-
ble
name
for
a
numeric
variable
and
a
character
variable.
Attempted
to
use
an
array
name
subscript
that
was
not
declared.
«
Expand
the
variables
with
the
DEFM
statement.
©
Change
the
variable
name
for
the
numeric
variable
and
character
variable.
e
Use
after
declaring
the
array
or
correct
the
array
name
subscript.
Error
7
Nesting
error
e
When
the
RETURN
statement
is
used
other
than
when
execut-
ing
a
subroutine.
®
When
the
FOR
statement
and
NEXT
statement
do
not
corre-
spond
or
when
the
variable
of
the
NEXT
statement
does
not
match
that
of
the
FOR
state-
ment.
e
When
the
subroutine
nesting
(calling
a
subroutine
from
a
subroutine)
exceeds
eight
levels.
Correspond
GOSUB
~
RETURN
or,
FOR
~
NEXT
correctly.
¢
Correct
the
subroutine
or
FOR
loop
nesting
level
with-
in
the
range.
243

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Casio FX-795P and is the answer not in the manual?

Casio FX-795P Specifications

General IconGeneral
BrandCasio
ModelFX-795P
CategoryDesktop
LanguageEnglish

Related product manuals