6. PRECAUTIONS FOR REPAIR: MODULE QW-2812
6-1. AC (ALL CLEAR) AND REMOVING OF MODULE
1. Perform AC (ALL CLEAR) when inserting a new battery, or else the memories and/ or counters may give
erratic displays.
Touch the AC contact and the main plate with the metallic tweezers.
The contact should be made for about two seconds.
6-2. ACCURACY CHECKING
Check the accuracy of the module with the quartz timer after switching the module to ACCURACY
CHECKING MODE.
The operations are shown below:
A) SWITCHING TO ACCURACY CHECKING MODE
While pressing the D button, press A and C buttons at the normal timekeeping mode.
Then all the segments are displayed and the LCD drive signals are changed to the static drive signal
of 32 Hz so that you can check the accuracy with the quartz timer.
B) CANCELLATION OF THE ACCURACY CHECKING MODE
Press any button.
Then the display is returned to its original state.
NOTE: The ACCURACY CHECKING MODE will
automatically return to the regular mode
in 1 ~ 2 hour(s) without any operation.