caso MCG30 Chef / MCG25 Chef 35
7.2 Fault indications
In the event of a fault, an error code will appear in the display; it describes the cause of the
fault.
Error code Description
E-01 Excessive temperature within cooking chamber
The overheating cut-out terminated the current program at a cooking
chamber temperature of 300°C.
Press the Stop button to acknowledge this fault.
The device can be re-activated after the cool down phase.
E-03 Sensor fault
The device has detected an error on a sensor and has terminated the
current programme. Press the Stop button to acknowledge this fault.
Please note
► If error messages continue to appear after an extended waiting period and restarting the
device, then the device will need to be sent to Customer Service to be inspected.
7.3 Causes and rectification of faults
The following table assists in localizing and rectifying minor faults
Error Possible cause Action
The selected program
will not start.
Device door is not closed Close device door
Power plug is not plugged in Plug in mains plug!
Fuse is not activated Activate fuse
The turntable turns
jerkily.
Dirt between the turntable
and the base of cooking
camber
Remove dirt
Dirt on rolling ring
Cooking vessel too large Use different cooking vessel
Food is not
sufficiently defrosted,
warmed up or cooked
after preset time has
elapsed.
Incorrectly selected time or
power level
Re-set time and power level
Repeat process
The device functions
but the cooking
chamber lighting
does not work.
Defective cooking chamber
light.
Have Service dept repair cooking
chamber light.