EasyManua.ls Logo

CC-ISOBUS CCI 1200 - User Manual

CC-ISOBUS CCI 1200
168 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
ISOBUS Terminal
CCI 1200
Operating instructions

Questions and Answers

  • W
    William BakerSep 12, 2025
    What to do if I get 'Alert / The backup has failed' on CC-ISOBUS CCI 1200 Touch terminals?
    • C
      Cody SmithSep 12, 2025
      If you receive an 'Alert / The backup has failed' message on your CC-ISOBUS Touch terminals, ensure that: * A flash drive is connected to the terminal. * The flash drive is functioning correctly. * The write-protection switch of the flash drive is in the "off" position. * The flash drive has at least 1GB of free storage.
  • S
    shane59Aug 25, 2025
    What to do if the connected implement is not displayed on CC-ISOBUS CCI 1200 Touch terminals?
    • E
      Elizabeth LewisAug 25, 2025
      If a connected implement isn't showing up on your CC-ISOBUS Touch terminal, there are a few potential causes: * The implement might not be correctly connected. Ensure the implement’s ISOBUS cable is securely connected to the tractor. * A bus terminator might be necessary. Check if the implement requires a bus terminator. * The UT configuration could be incorrect. Configure the UT of the terminal according to the manual.
  • L
    Louis WilliamsAug 25, 2025
    How to fix incorrect network password on CC-ISOBUS CCI 1200?
    • B
      Breanna ZhangAug 26, 2025
      If you're getting an 'Incorrect network password' error on your CC-ISOBUS Touch terminals, it means you've likely entered the wrong WiFi password. To correct this, press and hold the button with the WiFi network name in the selection list for two seconds. Then, select 'Edit', enter the correct password, and confirm with 'OK'.
  • K
    Kimberly AbbottSep 23, 2025
    What does 'Caution / The terminal is not connected with the ISOBUS' mean on CC-ISOBUS Touch terminals?
    • J
      Joseph FrostSep 23, 2025
      If you see the message 'Caution / The terminal is not connected with the ISOBUS' on your CC-ISOBUS Touch terminals, restart the terminal, disconnect the implement from the ISOBUS, wait 5 seconds, and then reconnect the implement to the ISOBUS.
  • A
    Amber LoganSep 13, 2025
    What to do if I get 'Alert / No flash drive connected' on CC-ISOBUS CCI 1200 Touch terminals?
    • W
      whernandezSep 13, 2025
      If you receive an 'Alert / No flash drive connected' message on your CC-ISOBUS Touch terminals, ensure that: * The flash drive is connected to the terminal. * The flash drive is functioning correctly. * The write-protection switch of the flash drive is in the "off" position. * The flash drive has at least 10MB of free storage.
  • K
    Kevin WillisSep 18, 2025
    What to do if I get 'Alert / The shape file could not be exported' on CC-ISOBUS CCI 1200 Touch terminals?
    • S
      stevenandersonSep 18, 2025
      If you receive an 'Alert / The shape file could not be exported' message on your CC-ISOBUS Touch terminals, repeat the process and leave the flash drive plugged in until the process has completed.
  • R
    Richard MyersSep 6, 2025
    What to do if CC-ISOBUS CCI 1200 Touch terminals are not connected with the ISOBUS?
    • K
      Kathleen DaySep 6, 2025
      If the CC-ISOBUS Touch terminal is not connected to the ISOBUS, try restarting the terminal. Alternatively, disconnect the implement from the ISOBUS, wait 5 seconds, and then reconnect it.
  • B
    bpetersonSep 6, 2025
    What to do if the selected UT number is already being used on CC-ISOBUS CCI 1200 Touch terminals?
    • K
      Kristina BarkerSep 7, 2025
      If the selected UT number is already being used on your CC-ISOBUS Touch terminal, please select another UT number and restart the terminal.
  • D
    Deanna JohnsonSep 23, 2025
    What to do if I get 'Alert / The report could not be exported' on CC-ISOBUS Touch terminals?
    • B
      bettyhallSep 23, 2025
      If you receive an 'Alert / The report could not be exported' message on your CC-ISOBUS Touch terminals, repeat the process and leave the flash drive plugged in until the process has completed.
  • E
    ebutlerAug 30, 2025
    What to do if shape file could not be exported on CC-ISOBUS CCI 1200 Touch terminals?
    • J
      Jamie HolmesAug 30, 2025
      If the shape file could not be exported from your CC-ISOBUS Touch terminals, it might be because you removed the flash drive before the action was completed. Repeat the process, making sure to leave the flash drive plugged in until the export is complete.

Summary

Safety and Precautions

Identification of Notes and Warnings

Explains how warning notes, cautions, and informational notes are identified and used in the manual.

Intended Use of the Terminal

Defines the exclusive intended use of the terminal in agriculture and manufacturer liability.

General Safety Instructions

Provides essential safety instructions for operation, handling, and maintenance to prevent hazards.

Electrical Device Installation Safety

Addresses safety considerations for installing electrical and electronic devices to avoid interference and hazards.

Setting Up and Configuring the Terminal

Implement Settings and Calibration

Tractor Configuration and Data Input

Details tractor data availability via ISOBUS/signal connector and guides on setting up tractor parameters.

Implement Configuration and Settings

Guides on adding, selecting, and configuring implements, including working width, type, and mounting.

GPS Receiver Setup and Configuration

Covers setting up the GPS receiver, including position and interface selection for accurate data.

ISOBUS Communication

Data Management and Application Maps

Map View for Precision Farming

Section Control Setup and Operation

Introduces the map view for Section Control and Rate Control, explaining its automatic section switching feature.

Troubleshooting and Error Resolution

General Failure Handling and Forced Shutdown

Provides guidance on behavior during technical failures, stopping work, finding solutions, and forced shutdown.

Operational Problems and Diagnostics

Lists common operational problems, their causes/remedies, and guides on capturing screenshots.

CC-ISOBUS CCI 1200 Specifications

General IconGeneral
Display Size12.1 inch
Resolution1280 x 800 pixels
TouchscreenYes
Operating Temperature-20°C to +60°C
ISOBUS CompatibilityYes
Touch TechnologyCapacitive
ProcessorARM Cortex-A9
Operating SystemLinux
RAM1 GB
Internal Storage8 GB
Protection ClassIP 65
ConnectivityEthernet, USB
IP RatingIP67

Related product manuals