The registers bellow must be set to the default values.
Register Name Range Description Default
Value
56 HUE 00 63 Hue 32
57 VOL 00 63 Volume 15
58 STNT 00 15 Stereo noise threshold 8
59 SPNT 00 15 SAP noise threshold 8
60 LA 00 15 Input level adjustment 7
61 ALW 00 31 Alignment for wideband 15
62 ALS 00 31 Alignment for spectral 15
Please, look the functions of registers bellow, before of change to the default value.
Description of service and factory registers
Register Name Range Description Default
Value
94 STBY 00 2 Standby 1
95 AV-2 00 1 AV2-Conected X
96 ASTU 00 3 Address Select of tuner 0
97 TUNE 00 1 Tuner protocol X
98 INI 00 00 Initialization 0
99 VSD 00 00 Vertical screen 0
Register 94 (STBY) Register 95 (AV-2)
Value Function Value Function
0 The TV set DON’T return to
the STANDBY, after of the
Power On.
0 1 AV input.
1 The TV set, always return to
the STANDBY, after of the
Power On
1 2 AV inputs.
2 Only to the factory. Don’t use
this value.
Register 96 (ASTU) Register 97 (TUNE)
Value Function Value Function
0 When the MAS pin of the
tuner is grounded.
0 To TUNER that run with
Europe protocol. (Ex.
UV1336S/A)
1 When the MAS pin of the
tuner is opened.
1 To TUNER that run with
U.S protocol.
2 When the MAS pin of the
tuner is between 0.4 and 0.6V
3 When the MAS pin of the
tuner is connected to the +5V.
Register 98 (INI) Register 99 (VSD)
Value Function Value Function
- Initialize all the registers to the
default value.
- To adjust the Screen.