35
Table for the choice of the injectors
INCREASE OF AIR NECESSARY FOR GAS COMBUSTION
(2 m
3
/h x kW)
BURNERS Air necessary for combustion [m
3
/h]
Auxiliary (A) 2,00
Semi-rapid (SR) 3,50
Rapid (R) 6,00
Triple-ring (TR) 7,00
Oven 12,40
Grill 9,30
G 30 - 28-30 mbar G 20
BURNERS G31- 37 mbar 20 mbar
Auxiliary (A) 1,00 0,30 27 50 - 72 (X) -
Semi-rapid (SR) 1,75 0,45 32 65 - 97 (Z) -
Rapid (R) 3,00 0,75 42 85 - 115 (Y) -
Triple-ring (TR) 3,50 1,50 65 95 - 135 (T) -
Oven 6,20 1,30 60 120 8 * 180 1,5 *
Grill 4,65 – – 107
fully open
* – 165 3 *
Nominal
Power
[kW]
Reduced
Power
[kW]
Ring opening
[mm]
Ø injector
[1/100 mm]
By-pass
[1/100 mm]
Ring opening
[mm]
Ø injector
[1/100 mm]
By-pass
[1/100 mm]