4.2 DISCHARGING FLUID FROM THE SUMP CLEANER
1. ATTACH THE SUMP CLEANER HOSE TO THE DISCHARGE PORT, AND CAP
THE SUCTION PORT.
2. RUN UNIT ON DISCHARGE MODE. (SEE INITIAL STARTUP 3.5, STEP 6.)
3. POINT NOZZLE AT THE TARGET WHERE THE FLUID IS TO BE DISPENSED,
SLOWLY OPEN DISCHARGE VALVE. SLUGS OF AIR WILL PASS THROUGH
HOSE WHEN TANK APPROACHES EMPTY. THESE SLUGS CAN CAUSE
ERRATIC FLUID FLOWS, BE PREPARED TO SHUT OF DISCHARGE VALVE
WHEN THIS OCCURS.
4.3 FILTER
1. FILTERING OF THE FLUID IS SPECIFIC TO YOU. SUMP CONDITIONS VARY
DUE TO ALL THE VARIABLES THAT OCCUR IN A MACHINE-TOOL SUMP.
WE INCLUDE MULTIPLE FILTER BAGS SO YOU CAN FIND WHAT WORKS
BEST FOR YOUR APPLICATION. FIRST-CLEANING CAN BE ESPECIALLY
DIFFICULT IF IT HAS NOT BEEN DONE ON A REGULAR BASIS. WE
SUGGEST STARTING WITH A COARSER BAG. ONCE ON A ROUTINE
BASIS, A FINER FILTER CAN BE USED.
2. FILTERS ARE REUSABLE AND WASHABLE IN LUKEWARM WATER.
3. MAKE SURE THAT PRESSURE IN SUMP CLEANER TANK IS RELIEVED
BEFORE EMPTYING FILTER.