SECTION 6 – TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSES CORRECTIVE ACTION
Power Supply
Make sure the unit is plugged into the proper voltage.
Circuit Breaker
Check electrical supply fuses or circuit breaker.
Vac Motor Brushes Check brushes; replace if needed.
Check hose for blockage.
Check gauge; replace if needed.
Tank is full; empty tank.
Make sure discharge valve is closed.
Air leakage; check gaskets and loose connections.
Reset vacuum relief to 13" Hg or replace.
Check hose for blockage.
Check for a build up of fines in tank bottom; clean if necessary.
Check that cap is on suction port.
Air leakage; check gaskets and loose connections.
Float Control Check float control; clean or replace.
Excessive Foaming
Consult coolant supplier.
Tank Turbulence Check to see if air is being sucked in the discharge.
Will not start
Check filter. If full, empty. If blinded, clean or go
to a coarser filter bag.
Vac/pres gauge reads
full vacuum but has no
suction.
Fluid coming out of
"Discharge" Tank-to -
Pump connection.
Vac/pres gauge reads
"0" vacuum.
Loss of suction
Will not discharge
Vac/Pres gauge reads
"6" psi.
Vac/Pres gauge reads
"0" psi.