SECTION 5 MAINTENANCE
TO GET THE HIGHEST PERFORMANCE FROM YOUR SUMP SHARK, IT IS
IMPORTANT TO KEEP IT WELL MAINTAINED. BELOW IS A MAINTENANCE GUIDE
THAT WILL KEEP YOUR SUMP CLEANER IN TOP-NOTCH, DEPENDABLE
CONDITION. ANY WORN OR DAMAGED PART SHOULD BE REPLACED
IMMEDIATELY. CECOR STOCKS SUMP CLEANER PARTS AND MOST CAN BE
SHIPPED THE SAME OR THE NEXT DAY. CALL 1-800-356-9042 TO ORDER
PARTS.
5.1 DAILY MAINTENANCE
1. CHECK THE VACUUM/PRESSURE GAUGE TO SEE THAT IT IS OPERATING
AND READING CORRECTLY. TANK PRESSURE SHOULD NOT EXCEED
PRESSURES OF 7 PSI AND VACUUMS OF 13” HG.
2. DEFECTIVE RELIEF VALVES SHOULD BE REPLACED IMMEDIATELY.
3. CHECK FOR GASKET LEAKS AND ANY TANK DAMAGE.
5.2 WEEKLY MAINTENANCE
1. INSPECT TANK FOR SLUDGE BUILD UP. CLEAN TANK IF NECESSARY.
WITH SOME APPLICATIONS, THE TANK MAY NEED TO BE CLEANED MORE
FREQUENTLY. ALWAYS CLEAN THE TANK
BETWEEN PUMPING DIFFERENT TYPES OF FLUIDS
OR MATERIALS.
2. CLEAN AND INSPECT TANK FLOAT CONTROL. SEE
THAT THE FLOAT BALL SEALS AGAINST THE
GASKET. THE FLOAT CONTROL ASSEMBLY CAN BE
ASSESSED THROUGH THE POT OPENING IN THE
SUMP CLEANER.
3. CLEAN THE FILTER BAG BY RINSING IT OUT IN
LUKEWARM WATER.
4. OPERATE THE 8 PSI PRESSURE RELIEF HANDLE
TO MAKE SURE IT IS WORKING.