5. TROUBLESHOOTING
Problem Possible cause Solution
The unit does not
work
Has the power cord
been disconnected?
Plug the power cord into the outlet.
Is the tank full indicator
on? (The tank is full or
not installed properly)
Empty the water in the tank and then
reinstall the tank.
Is the temperature of
the room above 35 ℃ or
below 5 ℃?
The protection device is activated and
the unit cannot operate.
The dehumidifying
function does not
work
Is the lter clogged?
Clean the lter as described in this
manual.
Is the intake duct
or discharge duct
obstructed?
Remove the obstruction from the
discharge duct or intake duct.
No air is discharged Is the lter clogged?
Clean the lter as described in this
manual.
The device
produces strange
noises when
operating
Is the unit tilted or
unsteady?
Move the unit to a stable, sturdy
location.
Is the lter clogged?
Clean the lter as described in this
manual.
6. TECHNICAL SPECIFICATIONS
Product reference: 05654/05655
Product: BigDry 9000 Expert Connected/BigDry 9000 Expert Black Connected
Power: 320 W
Voltage: 220-240 V 50 Hz
Frequency band: 2.4 GHz
Emission power: 13-14,5-17 dBm

Table of Contents