EasyManua.ls Logo

Cedar Ridge CRHD18T - User Manual

Cedar Ridge CRHD18T
68 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
VENT-FREE GAS LOGS
OWNER’S OPERATION AND
INSTALLATION MANUAL
MODELS
CRHD18T AND CRHD24T
Questions, problems, missing parts? Before returning to your retailer, call
our customer service department at 1-866-573-0674, 7:30 am - 4:15 pm CST,
Monday through Friday or email customerservice@usaprocom.com
PFS
®
US
WARNING: If the information in this manual is not
followed exactly, a re or explosion may result causing
property damage, personal injury or loss of life.
Do not store or use gasoline or other ammable va-
pors and liquids in the vicinity of this or any other
appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
Immediately call your gas supplier from a neighbors
phone. Follow the gas suppliers instructions.
If you cannot reach your gas supplier, call the re
department.
Installation and service must be performed by a quali-
ed installer, service agency or the gas supplier.
WARNING: This appliance is equipped for Natural and
Propane gas. Field conversion is not permitted other than
between natural or propane gases.
Cedar Ridge
hearth
®

Questions and Answers

  • M
    mleonardAug 17, 2025
    What to do if the Cedar Ridge Indoor Fireplace pilot lights but flame goes out?
    • J
      Julia DuncanAug 17, 2025
      If the pilot light on your Cedar Ridge Indoor Fireplace lights but the flame goes out when you release the control knob, several factors could be responsible: * Ensure the control knob is fully pressed in. * After the pilot lights, keep the control knob pressed in for 30 seconds. * Make sure the equipment shutoff valve is fully open. * Check that the thermocouple connection is snug at the control valve, hand-tightening it and then giving it an additional 1/4 turn. * If the pilot flame isn't touching the thermocouple, allowing it to cool, causing the pilot flame to extinguish, contact your local gas company or clean/replace the ODS/pilot assembly. * The thermocouple or control valve might be damaged and require replacement.
  • C
    craigmcdowellAug 19, 2025
    What to do if my Cedar Ridge Indoor Fireplace burner does not light after ODS/pilot is lit?
    • P
      Paul ColemanAug 19, 2025
      If the burner on your Cedar Ridge Indoor Fireplace doesn't light after the pilot is lit, it could be due to a clogged burner orifice, which you should clean or replace. It's also possible that the burner orifice diameter is too small, requiring a replacement. Finally, low inlet gas pressure could be the cause, in which case you should contact your local gas supplier.
  • A
    angelajohnsonAug 22, 2025
    What to do if the Cedar Ridge CRHD18T has a gas odor during combustion?
    • D
      Debra TuckerAug 22, 2025
      If you notice a gas odor during combustion with your Cedar Ridge Indoor Fireplace, it could be due to foreign matter between the control valve and burner, which requires a qualified service technician to remove. Alternatively, there may be a gas leak that needs to be located and corrected.
  • E
    Elizabeth WatsonAug 25, 2025
    What to do if my Cedar Ridge CRHD18T Indoor Fireplace has a yellow flame during burner combustion?
    • J
      Jenny BairdAug 26, 2025
      If your Cedar Ridge Indoor Fireplace exhibits a yellow flame during burner combustion, it could be due to insufficient air supply. Check the burner for any dirt or debris, and clean if necessary. A defective gas regulator or low inlet gas pressure could also be the cause. If the latter, contact your local gas supplier.
  • K
    Katherine JohnsonAug 28, 2025
    Why is there no spark at the ODS/pilot when pressing the ignitor button on my Cedar Ridge CRHD18T?
    • M
      Melissa WiseAug 28, 2025
      If there's no spark at the ODS/pilot when you press the ignitor button on your Cedar Ridge Indoor Fireplace, several issues could be the cause: * The ignitor electrode might be positioned incorrectly or broken, requiring replacement. * The ignitor electrode might not be connected to the ignitor cable, or the cable itself could be broken, both necessitating replacement. * The ignitor cable could be pinched or wet; free it from any obstructions and keep it dry. * The piezo ignitor might be bad, requiring replacement. * The battery might be low, so try replacing it.
  • T
    Tyler ByrdAug 30, 2025
    What to do if my Cedar Ridge CRHD18T produces unwanted odors?
    • D
      Dustin KellerAug 30, 2025
      If your Cedar Ridge Indoor Fireplace produces unwanted odors, it might be burning vapors from paint, hair spray, glues, etc. Open a window to ventilate the room and avoid using odor-causing products while the heater is running. A gas leak could also be the cause, so locate and correct any leaks. In propane/LP models, a low fuel supply can also cause odors; refill the supply tank.
  • M
    Marvin RuizSep 2, 2025
    What to do if my Cedar Ridge Indoor Fireplace burner backfires during combustion?
    • T
      Timothy BellSep 2, 2025
      If the burner on your Cedar Ridge Indoor Fireplace backfires during combustion, the burner orifice might be clogged or damaged, requiring cleaning or replacement. Alternatively, the burner itself or the gas regulator could be damaged, necessitating replacement.
  • D
    Dustin HansonSep 7, 2025
    Why is there a delayed ignition of burner in my Cedar Ridge CRHD18T?
    • B
      Barbara ObrienSep 8, 2025
      A delayed ignition of the burner in your Cedar Ridge Indoor Fireplace could be due to low manifold pressure, in which case you should contact your local gas supplier. It could also be due to a clogged burner orifice, which you can clean or replace.
  • R
    Rachel BradleySep 10, 2025
    Why does my Cedar Ridge Indoor Fireplace produce a whistling noise when the burner is lit?
    • A
      Adam ColeSep 12, 2025
      If your Cedar Ridge Indoor Fireplace produces a whistling noise when the burner is lit, it might be due to turning the control knob to the high position when the burner is cold; turn the control knob to the low position and let it warm up for a minute. Air in the gas line could also be the cause; operate the burner until the air is removed, and have the gas line checked by your local gas supplier. Blocked air passageways or a dirty burner orifice could also cause this issue; ensure minimum installation clearances and clean or replace the burner orifice.
  • E
    edward16Sep 13, 2025
    Why is there slight smoke or odor during initial operation of my Cedar Ridge CRHD18T Indoor Fireplace?
    • C
      cthompsonSep 13, 2025
      The slight smoke or odor during the initial operation of your Cedar Ridge Indoor Fireplace is likely due to residues from the manufacturing process. This issue should resolve itself after a few hours of operation.

Cedar Ridge CRHD18T Specifications

General IconGeneral
BrandCedar Ridge
ModelCRHD18T
CategoryIndoor Fireplace
LanguageEnglish

Related product manuals