Alarms
Thecoolingunithasbothanaudiblenotificationandavisualalarmindicator(shownin“red”onthe
controlpanel)thatareactivatedwhenanalarmistriggered.
Pleasenote
:thetemperaturealarm
(HA)isdisabledduringthefirst23hoursofoperationafterthecoolingunitispluggedinand/orturned
on.
AlarmCode Whatitmeans Whattodo
P1,P3
ProbeFailure
CallCellarProat877.726.8496
HA
Thetemperatureinside
thecellaristoowarm
(above70
°
Fformore
than1hour)
Checkifthecellarhasaleak
Checkifdoorwasleftopen
Lowertheambienttemperatures
HA2 Thecondensertemperature
istoohigh(above130
°
)
1. Turnthefanswitchtothe“High”fanspeed.
2. Turn“off”thecondensateevaporatorswitch.
3. Thereare2independentfansinthecoolingunit.
Makesurethatthecondenserfan(attherearofthe
coolingunit)isoperating.
4. Makesurethatthefilter(ifused)orthecoilsare
clean.
5. Checkforanyblockagesofthehotairintakeor
exhaust.
6. IfthecoolingunitisaVSx(ieexternal)unit,thehood
shouldbeshaded.
Ifyourunitcontinuestohaveissues,turnoffthecooling
unitandcallCellarProat877.726.8496oremail
info@cellarpro.com.
LA Thetemperatureinsidethe
cellaristoocold(below
45
°
F)
Raisetheambienttemperature
Raisethe“MinimumSetPoint”
LA2 Thetemperatureatthe
condensercoils(outsidethe
cabinet)hasdroppedbelow
thealarmtemperature
setting
TurnoffyourcoolingunitimmediatelyandcallCellarPro
at877.726.8496oremailinfo@cellarpro.com
