Questions and Answers

  • A
    Anthony JonesAug 12, 2025
    What to do if my Celli Brave 60 ES does not deliver water?
    • A
      Amber JarvisAug 12, 2025
      If your Celli Chiller isn't dispensing water, first ensure the main water tap is turned on. Next, check the water supply connection tube for any crushing or obstructions. Finally, verify that the plug is well inserted into the electricity supply.
  • D
    David CharlesAug 15, 2025
    Why my Celli Brave 60 ES Chiller dispenser does not start up?
    • G
      gregory94Aug 16, 2025
      If your Celli Chiller dispenser isn't starting up, first check that power is present. If the power supply is okay, it may be a thermostat failure, and you should call an authorised technician.
  • K
    Kyle BrownAug 19, 2025
    How to fix the issue if Celli Brave 60 ES Chiller dispensed product is not cold enough?
    • M
      Mr. Chase WaltersAug 20, 2025
      If the dispensed product from your Celli Chiller isn't cold enough, the ice bank may have run out; wait until it has fully reformed. Also, check that the incoming water temperature is lower than 32°C. If these steps don't resolve the issue, it could be a soda recirculation pump malfunction or inadequate insulation on the python, in which case you should call an authorised technician.
  • R
    Rose GreeneAug 23, 2025
    What to do if my Celli Brave 60 ES does not deliver sparkling water?
    • R
      Randy MooreAug 23, 2025
      If your Celli Chiller isn't dispensing sparkling water, first check if the CO cylinder has run out and replace it if necessary. Also, verify that the CO cylinder valve is open. If the issue persists, it may be due to an electronic control unit malfunction or pump failure, requiring you to call an authorised technician.
  • J
    Joseph ChristianAug 27, 2025
    Why is my Celli Chiller only dispensing water?
    • B
      Brandi ScottAug 27, 2025
      If your Celli Chiller is only dispensing water, the syrup tanks may have run out; replace them with new ones. Another possibility is that the syrup lines are obstructed; sanitise them as indicated in the relevant paragraph. Finally, check if there is no CO2; if so, replace the CO cylinder.
  • N
    Nicholas HernandezAug 30, 2025
    Why Celli Brave 60 ES cooling unit operates continually, and the water delivered is warm?
    • R
      Robert WellsAug 31, 2025
      If the cooling unit of your Celli Chiller operates continually, and the water delivered is warm, it may be due to a refrigerant gas leak, and you should call an authorised technician.
  • C
    Cynthia WalkerSep 3, 2025
    Why Celli Brave 60 ES cooling unit operates continually, and the water freezes?
    • P
      princejenniferSep 3, 2025
      If the cooling unit of your Celli Chiller operates continually, and the water freezes, it could be a thermostat failure, and you should call an authorised technician.
  • J
    James BishopSep 7, 2025
    How to fix a noisy water pump in my Celli Brave 60 ES Chiller?
    • A
      Andrew OdomSep 7, 2025
      If the water pump of your Celli Chiller is noisy, check that water is reaching the appliance.

Summary

Safety

Intended Use and Improper Use

Defines correct appliance usage, forbidden uses, and safety warnings for operators and users.

List of Hazards

Details potential dangers associated with CO2, electricity, gas cylinder position, and refrigerant.

Safety Cautions and Warnings

Outlines precautions for authorized staff, electrical requirements, sanitization, and low temperatures.

Machine Description and Operation

Operating Principle

Explains the cooling unit, ice bank, and heat exchange process for dispensing drinks.

Control Unit, Functions, and Alarms

Covers the energy saving unit, standard/optional functions, and alarm management.

Installation Procedures

Environmental Conditions and Electrical Requisites

Specifies suitable ambient temperatures and essential electrical connection standards.

CO2 and Electrical Connections

Provides instructions and safety warnings for connecting CO2 and final electrical connections.

Adjusting CO2 Supply and Dispensing Valves

Guides on adjusting CO2 pressure, checking for leaks, and adjusting dispensing valve ratios.

First Start-up Procedure

Details the initial sanitization and priming steps required before first use.

Using the Machine

Machine Start-up

Guides on connecting power, turning on the machine, and waiting for optimal operation.

Maintenance Procedures

Dispenser Sanitization and Check Valve Maintenance

Provides sanitization procedures for dispenser lines and cleaning/checking the liquid check valve.

Troubleshooting

Common Problems and Solutions

Provides a table of common issues, probable causes, and recommended remedies.