EasyManua.ls Logo

Celli Brave 90 ES - User Manual

Default Icon
68 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
30/10/2017
ED. 10
Celli S.p.A.
Via Casino Albini, 605
47842 - S. Giovanni in Marignano - Rimini - Italy
Tel. +39 0541 755211 - Fax +39 0541 759735
www.celli.com - celli@celli.com
Code 070344
TRANSLATION OF THE ORIGINAL
BRAVE 30 ESBRAVE 30 ES
BRAVE 30 ESBRAVE 30 ES
BRAVE 90 ESBRAVE 90 ES
BRAVE 90 ESBRAVE 90 ES
BRAVE 60 ESBRAVE 60 ES
BRAVE 60 ESBRAVE 60 ES
USE
USE
AND
AND
MAINTENANCE MANUAL
MAINTENANCE MANUAL
USE
USE
AND
AND
MAINTENANCE MANUAL
MAINTENANCE MANUAL

Table of Contents

Questions and Answers

  • Z
    Zachary OrtizAug 14, 2025
    What to do if my Celli Chiller does not deliver water?
    • W
      welchivanAug 14, 2025
      If your Celli Chiller isn't dispensing water, first ensure the main water tap is turned on. Next, check the water supply connection tube for any crushing or obstructions. Finally, verify that the plug is well inserted into the electricity supply.
  • S
    scott07Aug 17, 2025
    Why my Celli Brave 90 ES dispenser does not start up?
    • N
      Nathan WalkerAug 17, 2025
      If your Celli Chiller dispenser isn't starting up, first check that power is present. If the power supply is okay, it may be a thermostat failure, and you should call an authorised technician.
  • T
    Todd BeardAug 21, 2025
    How to fix the issue if Celli Chiller dispensed product is not cold enough?
    • S
      Stacey PalmerAug 21, 2025
      If the dispensed product from your Celli Chiller isn't cold enough, the ice bank may have run out; wait until it has fully reformed. Also, check that the incoming water temperature is lower than 32°C. If these steps don't resolve the issue, it could be a soda recirculation pump malfunction or inadequate insulation on the python, in which case you should call an authorised technician.
  • X
    xjohnsonAug 25, 2025
    What to do if my Celli Chiller does not deliver sparkling water?
    • N
      Nicholas GlassAug 25, 2025
      If your Celli Chiller isn't dispensing sparkling water, first check if the CO cylinder has run out and replace it if necessary. Also, verify that the CO cylinder valve is open. If the issue persists, it may be due to an electronic control unit malfunction or pump failure, requiring you to call an authorised technician.
  • S
    Susan DiazAug 28, 2025
    Why is my Celli Chiller only dispensing water?
    • R
      reedderekAug 29, 2025
      If your Celli Chiller is only dispensing water, the syrup tanks may have run out; replace them with new ones. Another possibility is that the syrup lines are obstructed; sanitise them as indicated in the relevant paragraph. Finally, check if there is no CO2; if so, replace the CO cylinder.
  • A
    Aaron CastilloSep 1, 2025
    Why Celli Brave 90 ES cooling unit operates continually, and the water delivered is warm?
    • W
      Wanda GreenSep 1, 2025
      If the cooling unit of your Celli Chiller operates continually, and the water delivered is warm, it may be due to a refrigerant gas leak, and you should call an authorised technician.
  • A
    awatkinsSep 5, 2025
    Why Celli Brave 90 ES cooling unit operates continually, and the water freezes?
    • K
      kevin97Sep 5, 2025
      If the cooling unit of your Celli Chiller operates continually, and the water freezes, it could be a thermostat failure, and you should call an authorised technician.
  • C
    charlesterrySep 8, 2025
    How to fix a noisy water pump in my Celli Brave 90 ES?
    • W
      wagnerrichardSep 9, 2025
      If the water pump of your Celli Chiller is noisy, check that water is reaching the appliance.

Summary

Safety

List of Hazards

Details potential dangers including CO2, electricity, gas cylinders, and refrigerants.

General Information

Symbols Used in the Manual

Explains the meaning of safety symbols (Danger, Warning, Caution) used throughout the manual.

Description of the Machine

Operating Principle

Explains how the cooling unit and hydraulic system function to dispense drinks.

Energy Saving Control Unit and Button Pad

Details the control unit and user interface for managing machine functions and alerts.

Technical Data

Provides specifications such as power supply, dimensions, refrigerant, and capacity for different models.

Installation

Positioning

Specifies requirements for placing the machine to ensure proper ventilation and operation.

Electrical Requisites

Outlines necessary electrical connections, earthing, and safety breaker requirements.

Connections

Covers the procedures for connecting water, syrup, CO2, and electrical supplies.

Preparing the Machine

Details steps for preparing the machine, including overflow connection and filling the water tank.

Water Intake Connection

Describes how to connect the machine to the water supply system and filter.

Carbon Dioxide (CO2) Connection

Provides instructions for connecting the CO2 cylinder and pressure reducer.

Electrical Connection

Details the final steps for connecting the machine to the electrical power supply.

Adjusting Carbon Dioxide (CO2) Supply

Explains how to set the correct CO2 pressure for the machine and syrup lines.

Checking for Leaks

Outlines the procedure for detecting leaks in the water, CO2, and syrup circuits.

Adjusting Dispensing Valves

Details how to calibrate the water-syrup ratio at the dispensing valves.

Using the Machine

Maintenance

Routine Maintenance

Lists daily checks and procedures required for consistent operation.

Replacing the Carbon Dioxide Cylinder (CO2)

Step-by-step guide on how to safely change the CO2 gas cylinder.

Sanitising the Dispenser

Provides procedures for sanitising the machine's product lines using recommended solutions.

Troubleshooting

Celli Brave 90 ES Specifications

General IconGeneral
BrandCelli
ModelBrave 90 ES
CategoryChiller
LanguageEnglish

Related product manuals