CELLO
Warning: Always test gas line for leaks at connector with soap water finishing all
connections.
How to disconnect a gas cylinder
g) Except for twin-cylinder installations with a changeover valve, turn off the gas tap if fitted to
the appliance. Wait until the burner and pilot light have gone out. For installations with a
changeover valve, it is only necessary to switch off the empty cylinder.
h) Replace the orange safety cap onto the empty cylinder.
GENERAL
Althoughall gasconnectionsonthegrill areleak testedatthefactorypriortoshipment,acomplete
gastightnesscheckmustbeperformedatthe installationsiteduetopossiblemishandling in
shipment,orexcessivepressureunknowinglybeing applied totheunit.Periodicallycheckthewhole
systemforleaksfollowingtheprocedureslisted below.Ifthesmellofgasisdetectedatanytime you
shouldimmediatelychecktheentiresystemforleaks.
BEFORETESTING
Makesurethatallpackingmaterialisremovedfrom thegrill includingtie-down straps.
DONOTSMOKEWHILELEAKTESTING. NEVERPERFORMLEAKTESTWITHANOPEN FLAME.
Makeasoapsolution ofonepartliquiddetergentand onepartwater.You
willneedaspraybottle,brush,or ragtoapply thesolution tothefittings.Fortheinitial
leaktest,makesuretheL.P.cylinderis80%full.
TO TEST
1. Makesurethecontrolvalvesarein theOFF position,andturnonthegassupply.
2. Checkallconnectionsfromthe gas regulatorand supplyvalveuptoandincluding
theconnectiontothemanifoldpipe assembly (thepipe thatgoestotheburners).Soap
bubbleswillappear where aleak ispresent.
3. Ifaleakispresent,immediatelyturnoffthegas supplyandtightentheleakyfittings.
4. Turnthegasbackonand recheck.
5. Shouldthegascontinuetoleakfromanyofthe fittings,turnoffthegassupply.
Install Regulator Hose Install Gas Tank & Regulator Hose
Do notusethegrill untilall connectionshave beencheckedanddonotleak.
ALWAYSCHECKFORLEAKSAFTEREVERY GAS TANKCHANGE
Checkallgassupplyfittingsforleaksbeforeeach use.Itishandytokeepaspraybottleofsoapy
waterneartheshut-offvalveofthegassupplyline. Sprayallthefittings.Bubblesindicateleaks.
8. Warning and safety points