4. Summary of SMS Commands
In the table below, XXXX is a four digit user password.
Modes and Functions
Description Command Explanation or Default SMS
Switch to Away Mode $XXXXA Away Mode Group A/Group B
Switch to Stay Mode $XXXXS Stay Mode Group A/Group B
Switch to Off Mode $XXXXO System Off Mode Group A/Group B
Switch to Monitor Mode $XXXXM Monitor Mode Group A/Group B
Silent Panic $XXXXH Silent Panic Group A/Group B
Panic $XXXXP Panic Group A/Group B
Reset E12 $XXXXr Reset Group A/Group B
Trigger Gas discharge $XXXXG9 Gas Triggered
Switch Output 1 On $XXXXB1 Output 1 On
Switch Output 1 Off $XXXXB0 Output 1 Off
Pulse Output 1 $XXXXB9 Output 1 pulse (Switch On and Off)
Switch Output 2 On $XXXXC1 Output 1 On
Switch Output 2 Off $XXXXC0 Output 1 Off
Pulse Output 2 $XXXXC9 Output 1 pulse (Switch On and Off)
Switch Output 3 On $XXXXD1 Output 1 On
Switch Output 3 Off $XXXXD0 Output 1 Off
Pulse Output 3 $XXXXD9 Output 1 pulse (Switch On and Off)
Switch Output 4 On $XXXXE1 Output 1 On
Switch Output 4 Off $XXXXE0 Output 1 Off
Pulse Output 4 $XXXXE9 Output 1 pulse (Switch On and Off)
Enable/Disable functions + Information requests
Enable Gas discharge $XXXXG1 Auto Gas Enabled
Disable Gas discharge $XXXXG0 Auto Gas Disabled
Disable 24 hr test signal $XXXXV Disable 24 H
Enable Seismic detector $XXXXp Seismic Detector On
Disable Seismic detector $XXXXq Seismic detector Off
Request signal strength $XXXXT /31 Signal Strength
Request alarm panel time $XXXXt Unit will reply with its current time and date setting
Request Timer Settings $XXXX* All timer settings will be sent to the requesting Cell
phone
Request Base and SMSC numbers $XXXXI Base station and SMSC numbers will be given
Request Cell numbers $XXXXJ All 4 programmed cell numbers will be given
Status request $XXXXL Status of alarm/Mains power/Battery
Request zone setup $XXXXs Reports the zone setup for the different modes
Set Outputs as Telemetry outputs $XXXX) See Section 1.5
Set Outputs as SMS outputs $XXXX( See Section 1.5
Disable SMS sending in Monitor- +
Stay mode
$XXXX> No SMS’s will be sent when panel is in monitor or
stay mode
Enable SMS sending in Monitor- +
Stay mode
$XXXX< All SMS’s will be sent when panel is in monitor or
stay mode
Table 3.
Summary of SMS Commands.

Table of Contents