7
The response given by the system is described above.
Deactivating Off Mode:
Off mode is deactivated by switching to any other mode (see the other
paragraphs for more detail).
1.1.4. Monitor Mode: (Used to monitor activity in zones without alarm activation)
Like all other modes, the active zones can be defined by the user.
If the E12 is switched to monitor mode by the Keypad or Key Ring then any
activation of a sensor in one of the active zones will result in the buzzer sounding
6 times. The corresponding zone number on the keypad will light up and stay on.
If the E12 is switched to monitor mode by SMS then any activation of a sensor in
one of the active zones will result in the buzzer sounding 6 times and an SMS will
be sent to the cell numbers only, No SMS will be sent to the Base number and
the telemetry outputs will not activate.
The corresponding zone number on the keypad will light up and stay on.
Every active zone will only send a maximum of 4 trigger events by SMS.
If the E12 is switched to monitor mode by SMS The E12 will send a ‘Monitor
mode activated’ SMS.
Activating Monitor Mode:
Monitor mode can be activated by SMS, key ring remote or keypad.
To activate by SMS, send $XXXXM to the E12.
To activate by Key ring remote, press the blue and red button
simultaneously.
To activate by keypad, enter user code, press the monitor button and
press enter.
The E12 will respond with 3 beeps on the internal buzzer.
Deactivating Monitor Mode:
Switch the E12 to Off Mode.
1.1.5. Away Monitor Mode: This is an Alternative Away Mode with different functions
for the zones that have been programmed to be on in Away and Monitor Modes.
The Away Monitor Mode combines the functions of zones on in Away Mode and
Zones on in Monitor Mode in the following Way.
Zones that are only on in Away mode when activated will result in the Siren
sounding for 4 minutes and an alarm SMS being sent to the Base number and
cell numbers, The telemetry Alarm output will also be activated.
Any further activation of these zones will result in the siren sounding again and
the SMS’s and telemetry signals being sent.
Zones that have been selected to be on in the Away and Monitor modes will
when activated result in the siren beeping 4 times and an alarm SMS ONLY