12
ENGLISH
4.5) Alarms/Warnings
These appear on the display during operation and inform the operator on the state of the tool.
Message Meaning Description
BATTERY
Ï
Ð
BATTERY
LOW
Replace or recharge the battery.
NOTE: when the battery voltage falls below a minimum safety
threshold, the tool will not start, although it is still possible to
end the work cycle in progress.
BATTERY
Ï

Ð
BATTERY
TEMPERATURE
HIGH
Remove the battery and wait until it cools down.
In order to cool quicker, it is possible to insert it into the supplied
battery charger supplied, thus making use of the specifi c AIR
COOLED” function.
30001
3
Ð
REQUEST
MAINTENANCE
No. of cycles to recommended maintenance is reached. The tool
continues to work however, it is recommended that it is sent to
Cembre for a complete overhaul (Ref. to section 7).
NOTE: this message, will reappear when the tool has been idle
for 30 s.
4.6) ERRORS: these appear during operation, combined with a beep and fl ashing LED Worklights,
to notify the operator of procedural or operational errors.
Message Error description Solution
ERROR
Ï
Ð
The pressure release button (6) was
pressed before the control parameters
were reached (Force/Pressure).
Repeat the work cycle and wait for the
motor to stop automatically.
001
Ï
Ð
Abnormal power consumption of the
motor for more than 3 seconds.
The tool stops.
Wait for the display to turn off (60 sec.)
or remove and re-insert the battery, then
re-start the tool.
If the error occurs frequently, contact
Cembre.
002
Ï
Ð
Output voltage of the pressure trans-
mitter is out of the pre-set range.
Repeat the work cycle; if the error occurs
frequently, contact Cembre.
003
Ï
Ð
Failure to reach the set pressure within
30 seconds continuous operation of
the tool.
Repeat the work cycle; if the error occurs
frequently, contact Cembre.
004
Ï
Ð
Overcharging of the battery with
protection tripping.
The tool stops.
Wait for the display to turn off (60 sec.)
or remove and re-insert the battery, then
re-start the tool.
If the error occurs frequently, contact
Cembre.
Error screens are displayed for about 30 seconds before being reset, but will display repeat-
edly in the event of permanent anomalies.