Specifications
Function Range Resolution Accuracy
AC Voltage 600V 0.1V ±(1.2% + 3 digits)
DC Voltage 600mV 0.1mV ±(0.7% + 3 digits)
6000mV 1mV ±(0.5% + 2 digits)
60V 0.01V ±(0.7% + 3 digits)
600V 0.1V ±(0.7% + 3 digits)
DC Current 600uA, 60mA, 600mA 0.1µA, 0.01mA,
0.1mA
±(1.0% + 3 digits)
10A 0.01A ±(1.2% + 5 digits)
Resistance 600Ω 0.1Ω ±(1.0% + 2 digits)
6000Ω, 60KΩ, 600KΩ 1Ω, 0.01kΩ, 0.1kΩ ±(0.8% + 2 digits)
60MΩ 0.01mΩ ±(2.0% + 5 digits)
Capacitance 9.999nF 0.001nF ±(4.0% + 10 digits)
99.99nF, 999.9nF 0.01nF, 0.1nF ±(4.0% + 5 digits)
9.999µF, 99.99µF, 999.9µF 0.001µF,
0.01µF, 0.1µF
±(4.0% + 5 digits)
9.999mF 0.001mF ± 10%
Sampling
Rate
~3 times/second
Storage
Temperature
Range: 14°F to 122°F
Operating
Temperature
Range: 32° - 104°F
Relative
Humidity
< 75% at 32°-86°F
< 50% at 86°-104°F
Operating
Altitude
7000ft. (2000meters)
maximum
Fuse Type 10A Jack: F 10A H 600V
Fuse Ø6x25mm
Battery 2x AAA batteries (included)