Page 14 For technical questions, please call 1-888-866-5797. Item 42202
fill the Hopper with new blasting
medium.
Blast Gun Maintenance:
After every use, clean out the Blast
Gun. To clean the gun:
1. Remove the Siphon Hose (8) from
the Blast Gun (7).
2. Operate the Gun for a few seconds to
clear the passages.
3. Turn off the shut-off valve.
4. Disconnect the air compressor.
5. Discharge any residual air from the
line and the Gun.
Seals
Sandblasting is a damaging
operation. In time, the internal parts
of the Blast Gun (7) will become
worn. When performance of the Blast
Gun decreases, take it to a qualified
service technician for repair.
Daily - Air Supply Maintenance:
Every day, perform maintenance
on the air supply according to
the component manufacturers’
instructions. The moisture filter must
be regularly drained. Performing
routine maintenance on the air supply
will allow the tool to operate more
safely and will also reduce wear on
the tool.